# CVE-2022-37928: Other in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays

> Attackers can bypass data authenticity checks in HPE Nimble Storage arrays, potentially compromising data integrity.

- **Severity:** High 8.0 (`CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H`)
- **Exploited in the wild:** Not known
- **Login needed:** Any signed-in user
- **Attackable:** Over the internet
- **Victim action needed:** A user has to click or open something
- **Fix available:** No
- **Published:** 3 Nov 2022
- **Updated:** 2 May 2025
- **Also known as:** GHSA-w43j-xjf7-hmp3

## What is CVE-2022-37928?

CVE-2022-37928 is a high-severity vulnerability in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays, published on 3 Nov 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.

### Official description

Insufficient Verification of Data Authenticity vulnerability in Hewlett Packard Enterprise HPE Nimble Storage Hybrid Flash Arrays and Nimble Storage Secondary Flash Arrays.

Weakness: CWE-345 (Insufficient Verification of Data Authenticity)

## Which versions are affected by CVE-2022-37928?

It affects 9 products.


Products: Hpe Hf20 Firmware, Hpe Hf20c Firmware, Hpe Hf20h Firmware, Hpe Hf40 Firmware, Hpe Hf40c Firmware, Hpe Hf60 Firmware, Hpe Hf60c Firmware, Hpe Sf100 Firmware, Hpe Sf300 Firmware.

## How do I fix CVE-2022-37928?

No fix has been published for CVE-2022-37928 yet. Limit exposure of the affected software until one is available.

## Is CVE-2022-37928 being exploited?

There is no known exploitation of CVE-2022-37928 in the wild and no public exploit code.

## Other vulnerabilities in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays

- [CVE-2022-37929](https://insights.sbomify.com/CVE-2022-37929/): Privilege escalation in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays (medium 6.7)
- [CVE-2022-37930](https://insights.sbomify.com/CVE-2022-37930/): Information disclosure in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays (medium 6.7)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2022-37928 and fix it if it is affected.

What it is: CVE-2022-37928 is a high-severity vulnerability in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays, published on 3 Nov 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.
Exploitation: There is no known exploitation of CVE-2022-37928 in the wild and no public exploit code.

Affected product: Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2022-37928/ (Markdown: https://insights.sbomify.com/CVE-2022-37928/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2022-37928
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2022-37928
- OSV: https://osv.dev/vulnerability/CVE-2022-37928

---
From sbomify Insights: https://insights.sbomify.com/CVE-2022-37928/
Summaries are generated and may contain mistakes; the official description above is the record.