# CVE-2022-37930: Information disclosure in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays

> Local attackers can disclose sensitive information from HPE Nimble Storage Hybrid and Secondary Flash Arrays.

- **Severity:** Medium 6.7 (`CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H`)
- **Exploited in the wild:** Not known
- **Login needed:** Any signed-in user
- **Attackable:** Local or same network only
- **Victim action needed:** A user has to click or open something
- **Fix available:** No
- **Published:** 3 Nov 2022
- **Updated:** 2 May 2025
- **Also known as:** GHSA-gx45-4v3f-xmjv

## What is CVE-2022-37930?

CVE-2022-37930 is a medium-severity vulnerability in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays, published on 3 Nov 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.

### Official description

A security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays and HPE Nimble Storage Secondary Flash Arrays which could potentially allow local disclosure of sensitive information.

Weakness: CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor)

## Which versions are affected by CVE-2022-37930?

It affects 9 products.


Products: Hpe Hf20 Firmware, Hpe Hf20c Firmware, Hpe Hf20h Firmware, Hpe Hf40 Firmware, Hpe Hf40c Firmware, Hpe Hf60 Firmware, Hpe Hf60c Firmware, Hpe Sf100 Firmware, Hpe Sf300 Firmware.

## How do I fix CVE-2022-37930?

No fix has been published for CVE-2022-37930 yet. Limit exposure of the affected software until one is available.

## Is CVE-2022-37930 being exploited?

There is no known exploitation of CVE-2022-37930 in the wild and no public exploit code.

## Other vulnerabilities in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays

- [CVE-2022-37928](https://insights.sbomify.com/CVE-2022-37928/): Other in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays (high 8.0)
- [CVE-2022-37929](https://insights.sbomify.com/CVE-2022-37929/): Privilege escalation in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays (medium 6.7)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2022-37930 and fix it if it is affected.

What it is: CVE-2022-37930 is a medium-severity vulnerability in Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays, published on 3 Nov 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.
Exploitation: There is no known exploitation of CVE-2022-37930 in the wild and no public exploit code.

Affected product: Hewlett Packard Enterprise (HPE) HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage Secondary Flash Arrays. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2022-37930/ (Markdown: https://insights.sbomify.com/CVE-2022-37930/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2022-37930
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2022-37930
- OSV: https://osv.dev/vulnerability/CVE-2022-37930

---
From sbomify Insights: https://insights.sbomify.com/CVE-2022-37930/
Summaries are generated and may contain mistakes; the official description above is the record.