{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-37952 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-37952 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-37952 is a medium-severity cross-site scripting vulnerability in GE Gas Power WorkstationST, published on 25 Aug 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-37952 and fix it if it is affected.\n\nWhat it is: CVE-2022-37952 is a medium-severity cross-site scripting vulnerability in GE Gas Power WorkstationST, published on 25 Aug 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-37952 in the wild and no public exploit code.\n\nAffected product: GE Gas Power WorkstationST. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-37952/ (Markdown: https://insights.sbomify.com/CVE-2022-37952/index.md)","id":"CVE-2022-37952","markdown":"https://insights.sbomify.com/CVE-2022-37952/index.md","name":"CVE-2022-37952","record":{"aliases":["GHSA-pvm3-6x23-6xwp"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"GE WorkstationST","requires_auth":"none","summary":"Reflected XSS in GE WorkstationST iHistorian Data Display allows attackers to compromise victim browsers in controlled industrial environments.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"GE GP","cpe":[{"product":"workstationst","vendor":"ge"}],"cvss":{"score":4.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (\u003cv07.09.15) could allow an attacker to compromise a victim's browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"WorkstationST - Reflected XSS in iHistorian Data Display Tags","id":"CVE-2022-37952","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"WorkstationST - Response Splitting in AM Gateway Challenge-Response","id":"CVE-2022-37953"},"packages":[],"prev":{"headline":"Not used in 2022","id":"CVE-2022-37951"},"products":["WorkstationST"],"published":"2022-08-25","related":[{"cvss_score":4.7,"headline":"WorkstationST - Response Splitting in AM Gateway Challenge-Response","id":"CVE-2022-37953","kev_date_added":null,"published":"2022-08-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["GE Gas Power"]},"summary":"Reflected XSS in GE WorkstationST iHistorian Data Display allows attackers to compromise victim browsers in controlled industrial environments.","url":"https://insights.sbomify.com/CVE-2022-37952/"}