{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-38069 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-38069 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-38069 is a medium-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-38069 and fix it if it is affected.\n\nWhat it is: CVE-2022-38069 is a medium-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-38069 in the wild and no public exploit code.\n\nAffected product: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-38069/ (Markdown: https://insights.sbomify.com/CVE-2022-38069/index.md)","id":"CVE-2022-38069","markdown":"https://insights.sbomify.com/CVE-2022-38069/index.md","name":"CVE-2022-38069","record":{"aliases":["GHSA-x446-rh2f-5gh9"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"patient monitor","requires_auth":"none","summary":"Hardcoded default credentials allow attackers with physical access to extract patient data or modify device parameters on Contec Health CMS8000 monitors.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cms8000_firmware","vendor":"contechealth"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Contec Health CMS8000","id":"CVE-2022-38069","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress Pop-up plugin \u003c= 1.1.5 - Privilege Escalation vulnerability","id":"CVE-2022-38070"},"packages":[],"prev":{"headline":"WordPress Export Post Info plugin \u003c= 1.1.0 - Authenticated Stored Cross-Site Scripting (XSS) vulnerability","id":"CVE-2022-38068"},"products":["CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor"],"published":"2022-09-13","related":[{"cvss_score":7.5,"headline":"Contec Health CMS8000","id":"CVE-2022-38100","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":6.8,"headline":"Contec Health CMS8000","id":"CVE-2022-36385","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":5.7,"headline":"Contec Health CMS8000","id":"CVE-2022-3027","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":3,"headline":"Contec Health CMS8000","id":"CVE-2022-38453","kev_date_added":null,"published":"2022-09-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Contec Health"]},"summary":"Hardcoded default credentials allow attackers with physical access to extract patient data or modify device parameters on Contec Health CMS8000 monitors.","url":"https://insights.sbomify.com/CVE-2022-38069/"}