{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-38123 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-38123 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-38123 is a high-severity code injection vulnerability in Secomea GateManager, published on 6 Dec 2022. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-38123 and fix it if it is affected.\n\nWhat it is: CVE-2022-38123 is a high-severity code injection vulnerability in Secomea GateManager, published on 6 Dec 2022. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-38123 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-38123/ (Markdown: https://insights.sbomify.com/CVE-2022-38123/index.md)","id":"CVE-2022-38123","markdown":"https://insights.sbomify.com/CVE-2022-38123/index.md","name":"CVE-2022-38123","record":{"aliases":["GHSA-q365-6hx4-82gp"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"high_privilege","summary":"A server administrator can inject code into the GateManager interface due to insufficient validation of plugin files.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager","vendor":"secomea"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Improper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.\n\nThis issue affects:\n\nSecomea GateManager\n\nversions prior to 10.0.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Insufficient validation of plugin files","id":"CVE-2022-38123","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Unwanted debug tool","id":"CVE-2022-38124"},"packages":[],"prev":{"headline":"POWERCOM CO., LTD. UPSMON PRO - Cleartext Transmission of Sensitive Information","id":"CVE-2022-38122"},"products":["GateManager"],"published":"2022-12-06","related":[{"cvss_score":9.9,"headline":"Logged-in Administrator may get unrestricted file system access","id":"CVE-2021-32008","kev_date_added":null,"published":"2022-03-04"},{"cvss_score":6.1,"headline":"Clear-text passwords in configuration files","id":"CVE-2022-4308","kev_date_added":null,"published":"2023-04-19"},{"cvss_score":5.5,"headline":"Potential vulnerabilities in GM login process","id":"CVE-2022-2752","kev_date_added":null,"published":"2022-12-09"},{"cvss_score":5,"headline":"Missing XSS guards on firmware page","id":"CVE-2021-32009","kev_date_added":null,"published":"2022-03-11"},{"cvss_score":5,"headline":"GateManager information leak for LinkManager Users","id":"CVE-2021-32006","kev_date_added":null,"published":"2022-03-07"},{"cvss_score":4.9,"headline":"GateManager debug interface is included in non-debug builds","id":"CVE-2023-0317","kev_date_added":null,"published":"2023-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-23","vendors":["Secomea"]},"summary":"A server administrator can inject code into the GateManager interface due to insufficient validation of plugin files.","url":"https://insights.sbomify.com/CVE-2022-38123/"}