{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-38453 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-38453 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-38453 is a low-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-38453 and fix it if it is affected.\n\nWhat it is: CVE-2022-38453 is a low-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-38453 in the wild and no public exploit code.\n\nAffected product: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-38453/ (Markdown: https://insights.sbomify.com/CVE-2022-38453/index.md)","id":"CVE-2022-38453","markdown":"https://insights.sbomify.com/CVE-2022-38453/index.md","name":"CVE-2022-38453","record":{"aliases":["GHSA-hv4m-6gjh-779j"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read","other"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"patient monitor","requires_auth":"high_privilege","summary":"Unstripped binaries on Contec Health CMS8000 monitors allow attackers to reverse engineer code and discover further vulnerabilities.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cms8000_firmware","vendor":"contechealth"}],"cvss":{"score":3,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-489","name":"Active Debug Code"}],"description":"Multiple binary application files on the CMS8000 device are compiled with 'not stripped' and 'debug_info' compilation settings. These compiler settings greatly decrease the level of effort for a threat actor to reverse engineer sensitive code and identify additional vulnerabilities.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Contec Health CMS8000","id":"CVE-2022-38453","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress Kraken.io Image Optimizer plugin \u003c= 2.6.5 - Cross-Site Request Forgery (CSRF) vulnerability","id":"CVE-2022-38454"},"packages":[],"prev":{"headline":"Command injection in Orbi Router RBR750","id":"CVE-2022-38452"},"products":["CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor"],"published":"2022-09-13","related":[{"cvss_score":7.5,"headline":"Contec Health CMS8000","id":"CVE-2022-38100","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":6.8,"headline":"Contec Health CMS8000","id":"CVE-2022-36385","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":5.7,"headline":"Contec Health CMS8000","id":"CVE-2022-3027","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":4.3,"headline":"Contec Health CMS8000","id":"CVE-2022-38069","kev_date_added":null,"published":"2022-09-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Contec Health"]},"summary":"Unstripped binaries on Contec Health CMS8000 monitors allow attackers to reverse engineer code and discover further vulnerabilities.","url":"https://insights.sbomify.com/CVE-2022-38453/"}