{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-39065 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-39065 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-39065 is a medium-severity denial of service vulnerability in Ikea TRÅDFRI gateway system, published on 14 Oct 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-39065 and fix it if it is affected.\n\nWhat it is: CVE-2022-39065 is a medium-severity denial of service vulnerability in Ikea TRÅDFRI gateway system, published on 14 Oct 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-39065 in the wild and no public exploit code.\n\nAffected product: Ikea TRÅDFRI gateway system. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-39065/ (Markdown: https://insights.sbomify.com/CVE-2022-39065/index.md)","id":"CVE-2022-39065","markdown":"https://insights.sbomify.com/CVE-2022-39065/index.md","name":"CVE-2022-39065","record":{"aliases":["GHSA-j9r7-xgvg-h2r5"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"IKEA smart home gateway","requires_auth":"none","summary":"An attacker can send a malformed Zigbee frame to crash the IKEA TRÅDFRI gateway, preventing control of connected lights.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SNPS","cpe":[{"product":"tradfri_gateway_e1526_firmware","vendor":"ikea"}],"cvss":{"score":6.5,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-241","name":"Improper Handling of Unexpected Data Type"}],"description":"A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in TRÅDFRI gateway system","id":"CVE-2022-39065","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"SQL injection in MF286R","id":"CVE-2022-39066"},"packages":[],"prev":{"headline":"Denial of service in TRÅDFRI smart lighting system","id":"CVE-2022-39064"},"products":["TRÅDFRI gateway system"],"published":"2022-10-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-05-15","vendors":["Ikea"]},"summary":"An attacker can send a malformed Zigbee frame to crash the IKEA TRÅDFRI gateway, preventing control of connected lights.","url":"https://insights.sbomify.com/CVE-2022-39065/"}