{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2022-41653 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-41653 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-41653 is a critical vulnerability in Daikin SVMPC1 , published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-41653 and fix it if it is affected.\n\nWhat it is: CVE-2022-41653 is a critical vulnerability in Daikin SVMPC1 , published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-41653 in the wild and no public exploit code.\n\nAffected product: Daikin SVMPC1 . No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-41653/ (Markdown: https://insights.sbomify.com/CVE-2022-41653/index.md)","id":"CVE-2022-41653","markdown":"https://insights.sbomify.com/CVE-2022-41653/index.md","name":"CVE-2022-41653","record":{"aliases":["GHSA-q7rw-9gg7-5wfw"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Daikin HVAC controller","requires_auth":"none","summary":"Attackers can use hardcoded credentials to gain unauthorized access and control Daikin HVAC systems.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"svmpc1","vendor":"daikinlatam"},{"product":"svmpc2","vendor":"daikinlatam"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in SVMPC1","id":"CVE-2022-41653","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"ghost vulnerable to unauthorized newsletter modification via improper access controls","id":"CVE-2022-41654"},"packages":[],"prev":{"headline":"WordPress Quiz And Survey Master plugin \u003c= 7.3.10 - Bypass vulnerability","id":"CVE-2022-41652"},"products":["SVMPC1 ","SVMPC2"],"published":"2022-12-13","related":[{"cvss_score":7.5,"headline":"Information disclosure in SVMPC1","id":"CVE-2022-38355","kev_date_added":null,"published":"2022-12-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Daikin"]},"summary":"Attackers can use hardcoded credentials to gain unauthorized access and control Daikin HVAC systems.","url":"https://insights.sbomify.com/CVE-2022-41653/"}