{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2022-41666 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-41666 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-41666 is a high-severity vulnerability in Schneider Electric EcoStruxure Operator Terminal Expert, published on 4 Nov 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-41666 and fix it if it is affected.\n\nWhat it is: CVE-2022-41666 is a high-severity vulnerability in Schneider Electric EcoStruxure Operator Terminal Expert, published on 4 Nov 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-41666 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Operator Terminal Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-41666/ (Markdown: https://insights.sbomify.com/CVE-2022-41666/index.md)","id":"CVE-2022-41666","markdown":"https://insights.sbomify.com/CVE-2022-41666/index.md","name":"CVE-2022-41666","record":{"aliases":["GHSA-9fmw-xp57-phr3"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial HMI software","requires_auth":"low_privilege","summary":"Local attackers can bypass signature verification to load malicious DLLs and execute arbitrary code in Schneider Electric HMI applications.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_operator_terminal_expert","vendor":"schneider-electric"},{"product":"pro-face_blue","vendor":"schneider-electric"}],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-347","name":"Improper Verification of Cryptographic Signature"}],"description":"A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in EcoStruxure Operator Terminal Expert","id":"CVE-2022-41666","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in EcoStruxure Operator Terminal Expert","id":"CVE-2022-41667"},"packages":[],"prev":{"headline":"A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions","id":"CVE-2022-41665"},"products":["EcoStruxure Operator Terminal Expert","Pro-face BLUE"],"published":"2022-11-04","related":[{"cvss_score":9.8,"headline":"Code injection in EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series","id":"CVE-2020-28221","kev_date_added":null,"published":"2021-01-25"},{"cvss_score":9.8,"headline":"Path traversal in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)","id":"CVE-2020-7497","kev_date_added":null,"published":"2020-06-16"},{"cvss_score":7.8,"headline":"Code injection in EcoStruxure™ Operator Terminal Expert","id":"CVE-2023-1049","kev_date_added":null,"published":"2023-06-14"},{"cvss_score":7.8,"headline":"SQL injection in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)","id":"CVE-2020-7493","kev_date_added":null,"published":"2020-06-16"},{"cvss_score":7.8,"headline":"Path traversal in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)","id":"CVE-2020-7494","kev_date_added":null,"published":"2020-06-16"},{"cvss_score":7,"headline":"Path traversal in EcoStruxure Operator Terminal Expert","id":"CVE-2022-41667","kev_date_added":null,"published":"2022-11-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-05-02","vendors":["Schneider Electric"]},"summary":"Local attackers can bypass signature verification to load malicious DLLs and execute arbitrary code in Schneider Electric HMI applications.","url":"https://insights.sbomify.com/CVE-2022-41666/"}