{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-41776 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-41776 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-41776 is a high-severity missing authorization vulnerability in Delta Electronics InfraSuite Device Master, published on 31 Oct 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-41776 and fix it if it is affected.\n\nWhat it is: CVE-2022-41776 is a high-severity missing authorization vulnerability in Delta Electronics InfraSuite Device Master, published on 31 Oct 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-41776 in the wild and no public exploit code.\n\nAffected product: Delta Electronics InfraSuite Device Master. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-41776/ (Markdown: https://insights.sbomify.com/CVE-2022-41776/index.md)","id":"CVE-2022-41776","markdown":"https://insights.sbomify.com/CVE-2022-41776/index.md","name":"CVE-2022-41776","record":{"aliases":["GHSA-6q8f-5hrg-whhc"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"ICS device master","requires_auth":"none","summary":"Unauthenticated attackers can modify configuration files to change administrative passwords in Delta Electronics InfraSuite Device Master.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"infrasuite_device_master","vendor":"deltaww"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in InfraSuite Device Master","id":"CVE-2022-41776","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"nadesiko3 allows remote attacker to inject invalid value to decodeURIComponent of nako3edit","id":"CVE-2022-41777"},"packages":[],"prev":{"headline":"Delta Electronics DIAEnergie SQL Injection","id":"CVE-2022-41775"},"products":["InfraSuite Device Master"],"published":"2022-10-31","related":[{"cvss_score":9.8,"headline":"Delta Electronics InfraSuite Device Master Exposed Dangerous Method Or Function","id":"CVE-2023-39226","kev_date_added":null,"published":"2023-11-30"},{"cvss_score":9.8,"headline":"Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data","id":"CVE-2023-47207","kev_date_added":null,"published":"2023-11-30"},{"cvss_score":9.8,"headline":"​Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data","id":"CVE-2023-34347","kev_date_added":null,"published":"2023-07-10"},{"cvss_score":9.8,"headline":"CVE-2023-1133","id":"CVE-2023-1133","kev_date_added":null,"published":"2023-03-27"},{"cvss_score":9.8,"headline":"CVE-2023-1136","id":"CVE-2023-1136","kev_date_added":null,"published":"2023-03-27"},{"cvss_score":9.8,"headline":"CVE-2023-1140","id":"CVE-2023-1140","kev_date_added":null,"published":"2023-03-27"},{"cvss_score":9.8,"headline":"Deserialization in InfraSuite Device Master","id":"CVE-2022-41778","kev_date_added":null,"published":"2023-01-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Delta Electronics"]},"summary":"Unauthenticated attackers can modify configuration files to change administrative passwords in Delta Electronics InfraSuite Device Master.","url":"https://insights.sbomify.com/CVE-2022-41776/"}