CVE-2022-42974 Cross-site scripting in n/a

Medium 4.8 Published Updated

Stored XSS in Kostal PIKO solar panel HMI allows attackers to inject scripts via filename parameter, potentially compromising user sessions.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Local or same network only
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2022-42974?

CVE-2022-42974 is a medium-severity cross-site scripting vulnerability in n/a, published on 21 Jun 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.

Official description

In Kostal PIKO 1.5-1 MP plus HMI OEM p 1.0.1, the web application for the Solar Panel is vulnerable to a Stored Cross-Site Scripting (XSS) attack on /file.bootloader.upload.html. The application fails to sanitize the parameter filename, in a POST request to /file.bootloader.upload.html for a system update, thus allowing one to inject HTML and/or JavaScript on the page that will then be processed and stored by the application. Any subsequent requests to pages that retrieve the malicious content will automatically exploit the vulnerability on the victim's browser. This also happens because the tag is loaded in the function innerHTML in the page HTML.

Weakness: CWE-79

Which versions are affected by CVE-2022-42974?

How do I fix CVE-2022-42974?

No fix has been published for CVE-2022-42974 yet. Limit exposure of the affected software until one is available.

Escape output for the context it lands in and set a strict Content Security Policy. Upgrading the affected component is the real fix. More about Cross-site scripting.

Is CVE-2022-42974 being exploited?

It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-42974 exists.

Sources

Also known as GHSA-8gvf-f484-h344.

Is CVE-2022-42974 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free