{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-4308 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-4308 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-4308 is a medium-severity vulnerability in Secomea GateManager, published on 19 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-4308 and fix it if it is affected.\n\nWhat it is: CVE-2022-4308 is a medium-severity vulnerability in Secomea GateManager, published on 19 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-4308 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-4308/ (Markdown: https://insights.sbomify.com/CVE-2022-4308/index.md)","id":"CVE-2022-4308","markdown":"https://insights.sbomify.com/CVE-2022-4308/index.md","name":"CVE-2022-4308","record":{"aliases":["GHSA-xr26-qphw-jcg8"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["account_takeover","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"none","summary":"Attackers can abuse authentication on SiteManager if configuration files containing plaintext passwords are leaked.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager","vendor":"secomea"}],"cvss":{"score":6.1,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-256","name":"Plaintext Storage of a Password"}],"description":"Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Clear-text passwords in configuration files","id":"CVE-2022-4308","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Subscribe2 \u003c 10.38 - User Deletion via CSRF","id":"CVE-2022-4309"},"packages":[],"prev":{"headline":"Pardakht Delkhah \u003c 2.9.3 - Unauthenticated Stored XSS","id":"CVE-2022-4307"},"products":["GateManager"],"published":"2023-04-19","related":[{"cvss_score":9.9,"headline":"Logged-in Administrator may get unrestricted file system access","id":"CVE-2021-32008","kev_date_added":null,"published":"2022-03-04"},{"cvss_score":8.7,"headline":"Insufficient validation of plugin files","id":"CVE-2022-38123","kev_date_added":null,"published":"2022-12-06"},{"cvss_score":5.5,"headline":"Potential vulnerabilities in GM login process","id":"CVE-2022-2752","kev_date_added":null,"published":"2022-12-09"},{"cvss_score":5,"headline":"Missing XSS guards on firmware page","id":"CVE-2021-32009","kev_date_added":null,"published":"2022-03-11"},{"cvss_score":5,"headline":"GateManager information leak for LinkManager Users","id":"CVE-2021-32006","kev_date_added":null,"published":"2022-03-07"},{"cvss_score":4.9,"headline":"GateManager debug interface is included in non-debug builds","id":"CVE-2023-0317","kev_date_added":null,"published":"2023-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Secomea"]},"summary":"Attackers can abuse authentication on SiteManager if configuration files containing plaintext passwords are leaked.","url":"https://insights.sbomify.com/CVE-2022-4308/"}