{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-43110 exists.","fix":"No fix has been published for CVE-2022-43110 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-43110 is a critical missing authorization vulnerability in n/a, published on 22 Aug 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-43110 and fix it if it is affected.\n\nWhat it is: CVE-2022-43110 is a critical missing authorization vulnerability in n/a, published on 22 Aug 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-43110 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-43110/ (Markdown: https://insights.sbomify.com/CVE-2022-43110/index.md)","id":"CVE-2022-43110","markdown":"https://insights.sbomify.com/CVE-2022-43110/index.md","name":"CVE-2022-43110","record":{"aliases":["GHSA-fg3v-43xx-v788"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"UPS management software","requires_auth":"none","summary":"Unauthenticated remote attackers can modify system configurations, change admin passwords, and shut down connected UPS devices in Voltronic Power ViewPower and PowerShield Netguard.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-425","name":"Direct Request"},{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-284","name":"Improper Access Control"}],"description":"Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2025-07-03","github_poc":1,"max_poc_stars":0,"metasploit":0,"nuclei":0,"refs":[{"date":"2025-07-03T05:18:22Z","kind":"github_poc","ref":"https://github.com/ready2disclose/CVE-2022-43110","stars":0,"title":"CVE-2022-43110"}],"tier":"weaponised"},"has_fix":null,"headline":"Missing authorization in n/a","id":"CVE-2022-43110","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2022-43117"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2022-43109"},"products":["n/a"],"published":"2025-08-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-22","vendors":["n/a"]},"summary":"Unauthenticated remote attackers can modify system configurations, change admin passwords, and shut down connected UPS devices in Voltronic Power ViewPower and PowerShield Netguard.","url":"https://insights.sbomify.com/CVE-2022-43110/"}