{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2022-43545 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-43545 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-43545 is a critical code injection vulnerability in Siemens POWER METER SICAM Q100, published on 8 Nov 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-43545 and fix it if it is affected.\n\nWhat it is: CVE-2022-43545 is a critical code injection vulnerability in Siemens POWER METER SICAM Q100, published on 8 Nov 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-43545 in the wild and no public exploit code.\n\nAffected product: Siemens POWER METER SICAM Q100. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-43545/ (Markdown: https://insights.sbomify.com/CVE-2022-43545/index.md)","id":"CVE-2022-43545","markdown":"https://insights.sbomify.com/CVE-2022-43545/index.md","name":"CVE-2022-43545","record":{"aliases":["GHSA-xvw3-v5p5-pf8m"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens power meter","requires_auth":"low_privilege","summary":"An authenticated remote attacker can execute arbitrary code or crash Siemens SICAM power meters via improper input validation in the web interface.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kg9501-0aa01-2aa1_firmware","vendor":"siemens"},{"product":"7kg9501-0aa31-2aa1_firmware","vendor":"siemens"}],"cvss":{"score":9.9,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P850 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10), SICAM P855 (All versions \u003c V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in POWER METER SICAM Q100","id":"CVE-2022-43545","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Other in POWER METER SICAM Q100","id":"CVE-2022-43546"},"packages":[],"prev":{"headline":"Other in KDDI +Message App for Android and for iOS, NTT DOCOMO +Message App for Android and for iOS, and SoftBank +Message App for Android and for iOS","id":"CVE-2022-43543"},"products":["POWER METER SICAM Q100","SICAM P850","SICAM P855"],"published":"2022-11-08","related":[{"cvss_score":9.9,"headline":"Other in POWER METER SICAM Q100","id":"CVE-2022-43439","kev_date_added":null,"published":"2022-11-08"},{"cvss_score":9.9,"headline":"Other in POWER METER SICAM Q100","id":"CVE-2022-43546","kev_date_added":null,"published":"2022-11-08"},{"cvss_score":7.5,"headline":"Auth bypass in POWER METER SICAM Q100","id":"CVE-2022-43398","kev_date_added":null,"published":"2022-11-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Siemens"]},"summary":"An authenticated remote attacker can execute arbitrary code or crash Siemens SICAM power meters via improper input validation in the web interface.","url":"https://insights.sbomify.com/CVE-2022-43545/"}