{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-44575 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-44575 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-44575 is a medium-severity cross-site scripting vulnerability in Siemens PLM Help Server V4.2, published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-44575 and fix it if it is affected.\n\nWhat it is: CVE-2022-44575 is a medium-severity cross-site scripting vulnerability in Siemens PLM Help Server V4.2, published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-44575 in the wild and no public exploit code.\n\nAffected product: Siemens PLM Help Server V4.2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-44575/ (Markdown: https://insights.sbomify.com/CVE-2022-44575/index.md)","id":"CVE-2022-44575","markdown":"https://insights.sbomify.com/CVE-2022-44575/index.md","name":"CVE-2022-44575","record":{"aliases":["GHSA-8j3w-2xwr-273w"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"PLM Help Server","requires_auth":"none","summary":"Reflected XSS in Siemens PLM Help Server allows attackers to execute malicious JavaScript via crafted links.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"plm_help_server","vendor":"siemens"}],"cvss":{"score":6.1,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A vulnerability has been identified in PLM Help Server V4.2 (All versions). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in PLM Help Server V4.2","id":"CVE-2022-44575","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress AgentEasy Properties plugin \u003c= 1.0.4 - Auth. Stored Cross-Site Scripting (XSS) vulnerability","id":"CVE-2022-44576"},"packages":[],"prev":{"headline":"Auth bypass in Ivanti Avalanche","id":"CVE-2022-44574"},"products":["PLM Help Server V4.2"],"published":"2022-12-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-22","vendors":["Siemens"]},"summary":"Reflected XSS in Siemens PLM Help Server allows attackers to execute malicious JavaScript via crafted links.","url":"https://insights.sbomify.com/CVE-2022-44575/"}