{"answers":{"affected":"It affects 55 products.","exploited":"There is no known exploitation of CVE-2022-45788 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-45788 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-45788 is a high-severity code injection vulnerability in Schneider Electric EcoStruxure Control Expert , published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-45788 and fix it if it is affected.\n\nWhat it is: CVE-2022-45788 is a high-severity code injection vulnerability in Schneider Electric EcoStruxure Control Expert , published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-45788 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Control Expert . No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-45788/ (Markdown: https://insights.sbomify.com/CVE-2022-45788/index.md)","id":"CVE-2022-45788","markdown":"https://insights.sbomify.com/CVE-2022-45788/index.md","name":"CVE-2022-45788","record":{"aliases":["GHSA-7q3m-cm45-5qq5"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric PLC","requires_auth":"none","summary":"Attackers can execute arbitrary code or cause denial of service by loading a malicious project file onto Schneider Electric PLCs.","user_interaction":"required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_control_expert","vendor":"schneider-electric"},{"product":"ecostruxure_process_expert","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp341000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420102_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342010_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342030_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342030h_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh582040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh582040c_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh582040s_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh584040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh584040c_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh584040s_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh586040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh586040c_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmeh586040s_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep581020_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep581020h_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep582020_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep582020h_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep582040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep582040h_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep582040s_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep583020_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep583040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep584020_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep584040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep584040s_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep585040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep585040c_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep586040_firmware","vendor":"schneider-electric"},{"product":"modicon_m580_bmep586040c_firmware","vendor":"schneider-electric"},{"product":"modicon_mc80_bmkc8020301_firmware","vendor":"schneider-electric"},{"product":"modicon_mc80_bmkc8020310_firmware","vendor":"schneider-electric"},{"product":"modicon_mc80_bmkc8030311_firmware","vendor":"schneider-electric"},{"product":"modicon_momentum_171cbu78090_firmware","vendor":"schneider-electric"},{"product":"modicon_momentum_171cbu98090_firmware","vendor":"schneider-electric"},{"product":"modicon_momentum_171cbu98091_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_1634m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_2634m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_2834m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_454m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_4634m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_554m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_5634m_firmware","vendor":"schneider-electric"},{"product":"modicon_premium_tsxp57_6634m_firmware","vendor":"schneider-electric"},{"product":"modicon_quantum_140cpu65150_firmware","vendor":"schneider-electric"},{"product":"modicon_quantum_140cpu65150c_firmware","vendor":"schneider-electric"},{"product":"modicon_quantum_140cpu65160_firmware","vendor":"schneider-electric"},{"product":"modicon_quantum_140cpu65160c_firmware","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-754","name":"Improper Check for Unusual or Exceptional Conditions"}],"description":"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026 integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in EcoStruxure Control Expert","id":"CVE-2022-45788","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in EcoStruxure Control Expert","id":"CVE-2022-45789"},"packages":[],"prev":{"headline":"Apache James MIME4J: Temporary File Information Disclosure in MIME4J TempFileStorageProvider","id":"CVE-2022-45787"},"products":["EcoStruxure Control Expert ","EcoStruxure Process Expert","Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)","Modicon M340 CPU (part numbers BMXP34*)","Modicon M580 CPU (part numbers BMEP* and BMEH*) ","Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)","Modicon MC80 (BMKC80)","Modicon Momentum Unity M1E Processor (171CBU*)"],"published":"2023-01-30","related":[{"cvss_score":9.8,"headline":"Auth bypass in EcoStruxure Control Expert","id":"CVE-2022-37300","kev_date_added":null,"published":"2022-09-12"},{"cvss_score":9.8,"headline":"Auth bypass in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28212","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":9.8,"headline":"Code injection in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)","id":"CVE-2020-7475","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-27976","kev_date_added":null,"published":"2023-04-18"},{"cvss_score":8.8,"headline":"Code injection in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28213","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":8.6,"headline":"Memory corruption in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions)","id":"CVE-2020-7560","kev_date_added":null,"published":"2020-12-11"},{"cvss_score":8.1,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-6408","kev_date_added":null,"published":"2024-02-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-05-29","vendors":["Schneider Electric"]},"summary":"Attackers can execute arbitrary code or cause denial of service by loading a malicious project file onto Schneider Electric PLCs.","url":"https://insights.sbomify.com/CVE-2022-45788/"}