{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-46141 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-46141 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-46141 is a medium-severity vulnerability in Siemens SIMATIC STEP 7 (TIA Portal), published on 12 Dec 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-46141 and fix it if it is affected.\n\nWhat it is: CVE-2022-46141 is a medium-severity vulnerability in Siemens SIMATIC STEP 7 (TIA Portal), published on 12 Dec 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-46141 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC STEP 7 (TIA Portal). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-46141/ (Markdown: https://insights.sbomify.com/CVE-2022-46141/index.md)","id":"CVE-2022-46141","markdown":"https://insights.sbomify.com/CVE-2022-46141/index.md","name":"CVE-2022-46141","record":{"aliases":["GHSA-2wph-4xpg-r884"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial automation software","requires_auth":"high_privilege","summary":"A local attacker can access CPU passwords entered by legitimate users in the hardware configuration of SIMATIC STEP 7.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_step_7","vendor":"siemens"}],"cvss":{"score":4.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"},{"id":"CWE-316","name":"Cleartext Storage of Sensitive Information in Memory"}],"description":"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SIMATIC STEP 7 (TIA Portal)","id":"CVE-2022-46141","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in RUGGEDCOM RM1224 LTE(4G) EU","id":"CVE-2022-46142"},"packages":[],"prev":{"headline":"Weak cryptography in RUGGEDCOM RM1224 LTE(4G) EU","id":"CVE-2022-46140"},"products":["SIMATIC STEP 7 (TIA Portal)"],"published":"2023-12-12","related":[{"cvss_score":7.8,"headline":"Missing authorization in SIMATIC STEP 7 (TIA Portal) V15","id":"CVE-2021-42029","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":6.8,"headline":"Other in n/a","id":"CVE-2015-1601","kev_date_added":null,"published":"2015-04-06"},{"cvss_score":4.7,"headline":"Information disclosure in n/a","id":"CVE-2016-7959","kev_date_added":null,"published":"2016-10-13"},{"cvss_score":4.4,"headline":"Auth bypass in n/a","id":"CVE-2015-1356","kev_date_added":null,"published":"2015-02-18"},{"cvss_score":2.5,"headline":"Information disclosure in n/a","id":"CVE-2016-7960","kev_date_added":null,"published":"2016-10-13"},{"cvss_score":2.1,"headline":"Information disclosure in n/a","id":"CVE-2015-1602","kev_date_added":null,"published":"2015-04-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-11-25","vendors":["Siemens"]},"summary":"A local attacker can access CPU passwords entered by legitimate users in the hardware configuration of SIMATIC STEP 7.","url":"https://insights.sbomify.com/CVE-2022-46141/"}