CVE-2022-48583 Command injection in SL 1

High 8.8 Published Updated

Attackers can execute arbitrary OS commands via unsanitized input in the dashboard scheduler, requiring immediate patching.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-48583?

CVE-2022-48583 is a high-severity command injection vulnerability in ScienceLogic SL 1, published on 9 Aug 2023. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A command injection vulnerability exists in the dashboard scheduler feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows for the injection of arbitrary commands to the underlying operating system.

Weakness: CWE-78

Which versions are affected by CVE-2022-48583?

It affects 1 product.

Products include Sciencelogic Sl1.

How do I fix CVE-2022-48583?

No fix has been published for CVE-2022-48583 yet. Limit exposure of the affected software until one is available.

Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.

Is CVE-2022-48583 being exploited?

There is no known exploitation of CVE-2022-48583 in the wild and no public exploit code.