{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2022-50975 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-50975 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-50975 is a high-severity authentication bypass vulnerability in Innomic AvibiaLine AVLE1 HD 5.0, published on 2 Feb 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-50975 and fix it if it is affected.\n\nWhat it is: CVE-2022-50975 is a high-severity authentication bypass vulnerability in Innomic AvibiaLine AVLE1 HD 5.0, published on 2 Feb 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-50975 in the wild and no public exploit code.\n\nAffected product: Innomic AvibiaLine AVLE1 HD 5.0. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-50975/ (Markdown: https://insights.sbomify.com/CVE-2022-50975/index.md)","id":"CVE-2022-50975","markdown":"https://insights.sbomify.com/CVE-2022-50975/index.md","name":"CVE-2022-50975","record":{"aliases":["GHSA-vf6m-whr4-pfvq"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation","data_modify"],"network_reachable":"yes","non_default_config":true,"product_category":"Vibration monitoring device","requires_auth":"none","summary":"Unauthenticated attackers can hijack active sessions to gain full administrative access to device configuration if ethernet access is enabled.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-346","name":"Origin Validation Error"}],"description":"An unauthenticated remote attacker is able to use an existing session id of a logged in user and gain full access to the device if configuration via ethernet is enabled.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Multiple Innomic VibroLine VLX and avibia AVLX allow unauthenticated access to device configuration","id":"CVE-2022-50975","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Innomic VibroLine Configurator and avibia Configurator allow unintended device reset via USB","id":"CVE-2022-50976"},"packages":[],"prev":{"headline":"This CVE ID has been rejected.","id":"CVE-2022-50974"},"products":["AvibiaLine AVLE1 HD 5.0","AvibiaLine AVLE2 HD 5.0","AvibiaLine AVLE4 HD 5.0","AvibiaLine AVLE6 HD 5.0","AvibiaLine AVLE8 HD 5.0","AvibiaLine AVLX1 HD 5.0","AvibiaLine AVLX2 HD 5.0","AvibiaLine AVLX4 HD 5.0","AvibiaLine AVLX6 HD 5.0","AvibiaLine AVLX8 HD 5.0","VibroLine VLE1 HD 4.0","VibroLine VLE1 HD 5.0","VibroLine VLE2 HD 4.0","VibroLine VLE2 HD 5.0","VibroLine VLE4 HD 4.0","VibroLine VLE4 HD 5.0","VibroLine VLE6 HD 4.0","VibroLine VLE6 HD 5.0","VibroLine VLE8 HD 4.0","VibroLine VLE8 HD 5.0","VibroLine VLX1 HD 4.0","VibroLine VLX1 HD 5.0","VibroLine VLX2 HD 4.0","VibroLine VLX2 HD 5.0","VibroLine VLX4 HD 4.0","VibroLine VLX4 HD 5.0","VibroLine VLX6 HD 4.0","VibroLine VLX6 HD 5.0","VibroLine VLX8 HD 4.0","VibroLine VLX8 HD 5.0"],"published":"2026-02-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-02","vendors":["Innomic","avibia"]},"summary":"Unauthenticated attackers can hijack active sessions to gain full administrative access to device configuration if ethernet access is enabled.","url":"https://insights.sbomify.com/CVE-2022-50975/"}