{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2023-0595 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-0595 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-0595 is a medium-severity vulnerability in Schneider Electric ClearSCADA , published on 24 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-0595 and fix it if it is affected.\n\nWhat it is: CVE-2023-0595 is a medium-severity vulnerability in Schneider Electric ClearSCADA , published on 24 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-0595 in the wild and no public exploit code.\n\nAffected product: Schneider Electric ClearSCADA . No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-0595/ (Markdown: https://insights.sbomify.com/CVE-2023-0595/index.md)","id":"CVE-2023-0595","markdown":"https://insights.sbomify.com/CVE-2023-0595/index.md","name":"CVE-2023-0595","record":{"aliases":["GHSA-27q3-84pw-qmf2"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA server software","requires_auth":"none","summary":"Attackers can inject malicious data into logs via network packets, causing misinterpretation of log files in Schneider Electric SCADA systems.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"clearscada","vendor":"schneider-electric"},{"product":"ecostruxure_geo_scada_expert_2019","vendor":"schneider-electric"},{"product":"ecostruxure_geo_scada_expert_2020","vendor":"schneider-electric"},{"product":"ecostruxure_geo_scada_expert_2021","vendor":"schneider-electric"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-116","name":"Improper Encoding or Escaping of Output"},{"id":"CWE-117","name":"Improper Output Neutralization for Logs"}],"description":"A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in ClearSCADA","id":"CVE-2023-0595","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in Kernel","id":"CVE-2023-0597"},"packages":[],"prev":{"headline":"Grafana vulnerable to Cross-site Scripting","id":"CVE-2023-0594"},"products":["ClearSCADA ","EcoStruxure Geo SCADA Expert 2019","EcoStruxure Geo SCADA Expert 2020","EcoStruxure Geo SCADA Expert 2021"],"published":"2023-02-24","related":[{"cvss_score":7.8,"headline":"Missing authorization in EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)","id":"CVE-2019-6854","kev_date_added":null,"published":"2020-01-06"},{"cvss_score":7.5,"headline":"Weak cryptography in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24318","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":7.5,"headline":"Denial of service in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24321","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":6.7,"headline":"Weak cryptography in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior)","id":"CVE-2021-22741","kev_date_added":null,"published":"2021-05-26"},{"cvss_score":5.9,"headline":"Other in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24319","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":5.9,"headline":"Other in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24320","kev_date_added":null,"published":"2022-02-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Schneider Electric"]},"summary":"Attackers can inject malicious data into logs via network packets, causing misinterpretation of log files in Schneider Electric SCADA systems.","url":"https://insights.sbomify.com/CVE-2023-0595/"}