{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2023-0808 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-0808 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-0808 is a low-severity vulnerability in Bosswerk Inverter, published on 13 Feb 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-0808 and fix it if it is affected.\n\nWhat it is: CVE-2023-0808 is a low-severity vulnerability in Bosswerk Inverter, published on 13 Feb 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-0808 in the wild and no public exploit code.\n\nAffected product: Bosswerk Inverter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-0808/ (Markdown: https://insights.sbomify.com/CVE-2023-0808/index.md)","id":"CVE-2023-0808","markdown":"https://insights.sbomify.com/CVE-2023-0808/index.md","name":"CVE-2023-0808","record":{"aliases":["GHSA-j998-c4rh-83vq"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["security_bypass","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Solar Inverter","requires_auth":"none","summary":"Attackers with physical access can bypass authentication using a hard-coded password to gain control of the solar inverter's access point settings.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"inverter_firmware","vendor":"bosswerk"},{"product":"inverter_firmware","vendor":"deyeinverter"},{"product":"inverter_firmware","vendor":"revolt-power"}],"cvss":{"score":3.9,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Deye/Revolt/Bosswerk Inverter Access Point Setting hard-coded password","id":"CVE-2023-0808","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2023"},"n_packages":0,"n_references":3,"next":{"headline":"Denial of service in Mosquitto","id":"CVE-2023-0809"},"packages":[],"prev":{"headline":"Missing authorization in GitLab","id":"CVE-2023-0805"},"products":["Inverter"],"published":"2023-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Bosswerk","Deye","Revolt"]},"summary":"Attackers with physical access can bypass authentication using a hard-coded password to gain control of the solar inverter's access point settings.","url":"https://insights.sbomify.com/CVE-2023-0808/"}