{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-0888 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-0888 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-0888 is a medium-severity code injection vulnerability in B. Braun  Space Battery Pack SP with Wi-Fi, published on 13 Mar 2023. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-0888 and fix it if it is affected.\n\nWhat it is: CVE-2023-0888 is a medium-severity code injection vulnerability in B. Braun  Space Battery Pack SP with Wi-Fi, published on 13 Mar 2023. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-0888 in the wild and no public exploit code.\n\nAffected product: B. Braun  Space Battery Pack SP with Wi-Fi. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-0888/ (Markdown: https://insights.sbomify.com/CVE-2023-0888/index.md)","id":"CVE-2023-0888","markdown":"https://insights.sbomify.com/CVE-2023-0888/index.md","name":"CVE-2023-0888","record":{"aliases":["GHSA-9w87-qf4h-4fc6"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical device battery pack","requires_auth":"high_privilege","summary":"Authenticated attackers can inject code into the Wi-Fi battery pack web server to gain root access, enabling further attacks on the infusion pump.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"B.Braun","cpe":[{"product":"battery-pack_sp_with_wifi_firmware","vendor":"bbraun"}],"cvss":{"score":4.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"},{"id":"CWE-95","name":"Improper Neutralization of Directives in Dynamically Evaluated Code"}],"description":"An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authenticated eval injection in B. Braun Space Battery pack SP with Wi-Fi","id":"CVE-2023-0888","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2023"},"n_packages":0,"n_references":2,"next":{"headline":"TF Random Numbers \u003c 2.0.1 - Subscriber+ Arbitrary Option Update","id":"CVE-2023-0889"},"packages":[],"prev":{"headline":"phjounin TFTPD64-SE tftpd64_svc.exe unquoted search path","id":"CVE-2023-0887"},"products":["Space Battery Pack SP with Wi-Fi"],"published":"2023-03-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-27","vendors":["B. Braun "]},"summary":"Authenticated attackers can inject code into the Wi-Fi battery pack web server to gain root access, enabling further attacks on the infusion pump.","url":"https://insights.sbomify.com/CVE-2023-0888/"}