{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-1548 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-1548 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-1548 is a medium-severity vulnerability in Schneider Electric EcoStruxure Control Expert, published on 18 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-1548 and fix it if it is affected.\n\nWhat it is: CVE-2023-1548 is a medium-severity vulnerability in Schneider Electric EcoStruxure Control Expert, published on 18 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-1548 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Control Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-1548/ (Markdown: https://insights.sbomify.com/CVE-2023-1548/index.md)","id":"CVE-2023-1548","markdown":"https://insights.sbomify.com/CVE-2023-1548/index.md","name":"CVE-2023-1548","record":{"aliases":["GHSA-w35h-r9ff-45q4"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial control software","requires_auth":"low_privilege","summary":"A local user can cause a denial of service in EcoStruxure Control Expert via improper privilege management in the console server service.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_control_expert","vendor":"schneider-electric"}],"cvss":{"score":5.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"}],"description":"A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in EcoStruxure Control Expert","id":"CVE-2023-1548","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Ad Inserter \u003c 2.7.27 - Admin+ PHP Object Injection","id":"CVE-2023-1549"},"packages":[],"prev":{"headline":"SQLi in Elra Computers Parkmatik","id":"CVE-2023-1547"},"products":["EcoStruxure Control Expert"],"published":"2023-04-18","related":[{"cvss_score":9.8,"headline":"Auth bypass in EcoStruxure Control Expert","id":"CVE-2022-37300","kev_date_added":null,"published":"2022-09-12"},{"cvss_score":9.8,"headline":"Auth bypass in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28212","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":9.8,"headline":"Code injection in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)","id":"CVE-2020-7475","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-27976","kev_date_added":null,"published":"2023-04-18"},{"cvss_score":8.8,"headline":"Code injection in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28213","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":8.6,"headline":"Memory corruption in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions)","id":"CVE-2020-7560","kev_date_added":null,"published":"2020-12-11"},{"cvss_score":8.1,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-6408","kev_date_added":null,"published":"2024-02-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Schneider Electric"]},"summary":"A local user can cause a denial of service in EcoStruxure Control Expert via improper privilege management in the console server service.","url":"https://insights.sbomify.com/CVE-2023-1548/"}