{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-22803 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-22803 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-22803 is a high-severity missing authorization vulnerability in LS Electric XBC-DN32U, published on 15 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-22803 and fix it if it is affected.\n\nWhat it is: CVE-2023-22803 is a high-severity missing authorization vulnerability in LS Electric XBC-DN32U, published on 15 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-22803 in the wild and no public exploit code.\n\nAffected product: LS Electric XBC-DN32U. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-22803/ (Markdown: https://insights.sbomify.com/CVE-2023-22803/index.md)","id":"CVE-2023-22803","markdown":"https://insights.sbomify.com/CVE-2023-22803/index.md","name":"CVE-2023-22803","record":{"aliases":["GHSA-ww7q-jpm3-9c64"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"PLC controller","requires_auth":"none","summary":"An attacker can arbitrarily change the mode of the LS ELECTRIC XBC-DN32U PLC due to missing authentication for critical functions.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"xbc-dn32u_firmware","vendor":"ls-electric"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"CVE-2023-22803","id":"CVE-2023-22803","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"CVE-2023-22804","id":"CVE-2023-22804"},"packages":[],"prev":{"headline":"ReDoS based DoS vulnerability in GlobalID","id":"CVE-2023-22799"},"products":["XBC-DN32U"],"published":"2023-02-15","related":[{"cvss_score":9.8,"headline":"CVE-2023-22807","id":"CVE-2023-22807","kev_date_added":null,"published":"2023-02-15"},{"cvss_score":9.1,"headline":"CVE-2023-0102","id":"CVE-2023-0102","kev_date_added":null,"published":"2023-02-15"},{"cvss_score":9.1,"headline":"CVE-2023-22804","id":"CVE-2023-22804","kev_date_added":null,"published":"2023-02-15"},{"cvss_score":7.5,"headline":"CVE-2023-0103","id":"CVE-2023-0103","kev_date_added":null,"published":"2023-02-15"},{"cvss_score":7.5,"headline":"CVE-2023-22806","id":"CVE-2023-22806","kev_date_added":null,"published":"2023-02-15"},{"cvss_score":6.5,"headline":"CVE-2023-22805","id":"CVE-2023-22805","kev_date_added":null,"published":"2023-02-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-01-16","vendors":["LS Electric"]},"summary":"An attacker can arbitrarily change the mode of the LS ELECTRIC XBC-DN32U PLC due to missing authentication for critical functions.","url":"https://insights.sbomify.com/CVE-2023-22803/"}