{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-24504 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-24504 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-24504 is a high-severity server-side request forgery vulnerability in Electra Central AC unit, published on 17 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-24504 and fix it if it is affected.\n\nWhat it is: CVE-2023-24504 is a high-severity server-side request forgery vulnerability in Electra Central AC unit, published on 17 Apr 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-24504 in the wild and no public exploit code.\n\nAffected product: Electra Central AC unit. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-24504/ (Markdown: https://insights.sbomify.com/CVE-2023-24504/index.md)","id":"CVE-2023-24504","markdown":"https://insights.sbomify.com/CVE-2023-24504/index.md","name":"CVE-2023-24504","record":{"aliases":["GHSA-c5rj-26pj-c7cr"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Central AC unit","requires_auth":"none","summary":"An adjacent attacker can force the AC unit to connect to a malicious update server, potentially leading to code execution or data exposure.","user_interaction":"not_required","vuln_class":"ssrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"INCD","cpe":[{"product":"central_ac_unit_firmware","vendor":"electra-air"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[],"description":"Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server","id":"CVE-2023-24504","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"ssrf","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Milesight NCR/Camera CWE-200: Exposure of Sensitive Information","id":"CVE-2023-24505"},"packages":[],"prev":{"headline":"Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW","id":"CVE-2023-24503"},"products":["Central AC unit"],"published":"2023-04-17","related":[{"cvss_score":9.8,"headline":"Electra Central AC unit – Hardcoded Credentials","id":"CVE-2023-24501","kev_date_added":null,"published":"2023-04-17"},{"cvss_score":7.5,"headline":"Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW","id":"CVE-2023-24500","kev_date_added":null,"published":"2023-04-17"},{"cvss_score":7.5,"headline":"Electra Central AC unit – Easily calculated password","id":"CVE-2023-24502","kev_date_added":null,"published":"2023-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-06","vendors":["Electra"]},"summary":"An adjacent attacker can force the AC unit to connect to a malicious update server, potentially leading to code execution or data exposure.","url":"https://insights.sbomify.com/CVE-2023-24504/"}