{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-25018 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-25018 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-25018 is a medium-severity cross-site scripting vulnerability in Rifartek IOT Wall, published on 27 Mar 2023. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-25018 and fix it if it is affected.\n\nWhat it is: CVE-2023-25018 is a medium-severity cross-site scripting vulnerability in Rifartek IOT Wall, published on 27 Mar 2023. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-25018 in the wild and no public exploit code.\n\nAffected product: Rifartek IOT Wall. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-25018/ (Markdown: https://insights.sbomify.com/CVE-2023-25018/index.md)","id":"CVE-2023-25018","markdown":"https://insights.sbomify.com/CVE-2023-25018/index.md","name":"CVE-2023-25018","record":{"aliases":["GHSA-8prw-vrjf-w7gx"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"IOT Wall","requires_auth":"low_privilege","summary":"An authenticated attacker can inject JavaScript into the Rifartek IOT Wall transportation function to execute arbitrary scripts in victim browsers.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"twcert","cpe":[{"product":"iot_wall","vendor":"rifartek"}],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"RIFARTEK IOT Wall transportation function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can inject JavaScript to perform reflected XSS (Reflected Cross-site scripting) attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rifartek IOT Wall - Reflected XSS","id":"CVE-2023-25018","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress Chaty Plugin \u003c= 3.0.9 is vulnerable to Cross Site Scripting (XSS)","id":"CVE-2023-25019"},"packages":[],"prev":{"headline":"Rifartek IOT Wall - Broken Access Control","id":"CVE-2023-25017"},"products":["IOT Wall"],"published":"2023-03-27","related":[{"cvss_score":8.1,"headline":"Rifartek IOT Wall - Broken Access Control","id":"CVE-2023-25017","kev_date_added":null,"published":"2023-03-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-19","vendors":["Rifartek"]},"summary":"An authenticated attacker can inject JavaScript into the Rifartek IOT Wall transportation function to execute arbitrary scripts in victim browsers.","url":"https://insights.sbomify.com/CVE-2023-25018/"}