{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-2569 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-2569 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-2569 is a high-severity memory corruption vulnerability in Schneider Electric EcoStruxure Foxboro DCS Control Core Services, published on 14 Jun 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-2569 and fix it if it is affected.\n\nWhat it is: CVE-2023-2569 is a high-severity memory corruption vulnerability in Schneider Electric EcoStruxure Foxboro DCS Control Core Services, published on 14 Jun 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-2569 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Foxboro DCS Control Core Services. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-2569/ (Markdown: https://insights.sbomify.com/CVE-2023-2569/index.md)","id":"CVE-2023-2569","markdown":"https://insights.sbomify.com/CVE-2023-2569/index.md","name":"CVE-2023-2569","record":{"aliases":["GHSA-8whh-hcfg-87f2"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Foxboro DCS Control Core","requires_auth":"low_privilege","summary":"Local attackers can exploit an out-of-bounds write in the Foxboro.sys driver to escalate privileges and execute kernel code.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_foxboro_dcs_control_core_services","vendor":"schneider-electric"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"description":"A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service,\nelevation of privilege, and potentially kernel execution when a malicious actor with local user\naccess crafts a script/program using an IOCTL call in the Foxboro.sys driver.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in EcoStruxure Foxboro DCS Control Core Services","id":"CVE-2023-2569","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in EcoStruxure Foxboro DCS Control Core Services","id":"CVE-2023-2570"},"packages":[],"prev":{"headline":"Photo Gallery by Ays \u003c 5.1.7 - Reflected XSS","id":"CVE-2023-2568"},"products":["EcoStruxure Foxboro DCS Control Core Services"],"published":"2023-06-14","related":[{"cvss_score":7.8,"headline":"Privilege escalation in EcoStruxure Foxboro DCS Core Control Services","id":"CVE-2024-5681","kev_date_added":null,"published":"2024-07-11"},{"cvss_score":7.1,"headline":"Memory corruption in EcoStruxure Foxboro DCS Core Control Services","id":"CVE-2024-5679","kev_date_added":null,"published":"2024-07-11"},{"cvss_score":7.1,"headline":"Denial of service in EcoStruxure Foxboro DCS Core Control Services","id":"CVE-2024-5680","kev_date_added":null,"published":"2024-07-11"},{"cvss_score":7,"headline":"Denial of service in EcoStruxure Foxboro DCS Control Core Services","id":"CVE-2023-2570","kev_date_added":null,"published":"2023-06-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-01-02","vendors":["Schneider Electric"]},"summary":"Local attackers can exploit an out-of-bounds write in the Foxboro.sys driver to escalate privileges and execute kernel code.","url":"https://insights.sbomify.com/CVE-2023-2569/"}