{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2023-25931 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-25931 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-25931 is a medium-severity authentication bypass vulnerability in Medtronic InsterStim Applications, published on 1 Mar 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-25931 and fix it if it is affected.\n\nWhat it is: CVE-2023-25931 is a medium-severity authentication bypass vulnerability in Medtronic InsterStim Applications, published on 1 Mar 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-25931 in the wild and no public exploit code.\n\nAffected product: Medtronic InsterStim Applications. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-25931/ (Markdown: https://insights.sbomify.com/CVE-2023-25931/index.md)","id":"CVE-2023-25931","markdown":"https://insights.sbomify.com/CVE-2023-25931/index.md","name":"CVE-2023-25931","record":{"aliases":["GHSA-crgr-72p3-3g72"],"analysis":{"component_type":"mobile_application","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medtronic clinician app","requires_auth":"none","summary":"Attackers with physical access can bypass password controls to gain unauthorized control over clinician therapy parameters in Medtronic apps.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Medtronic","cpe":[{"product":"interstim_x_clinician","vendor":"medtronic"},{"product":"micro_clinician","vendor":"medtronic"}],"cvss":{"score":6.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-620","name":"Unverified Password Change"}],"description":"Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app.  Changes still cannot be made outside of the established therapy parameters of the programmer.  For unauthorized access to occur, an individual would need physical access to the Smart Programmer.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic Micro Clinician \u0026 InterStim X Clinician App Password Reset Issue","id":"CVE-2023-25931","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Hermes","id":"CVE-2023-25933"},"packages":[],"prev":{"headline":"IBM Db2 denial of service","id":"CVE-2023-25930"},"products":["InsterStim Applications"],"published":"2023-03-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-07","vendors":["Medtronic"]},"summary":"Attackers with physical access can bypass password controls to gain unauthorized control over clinician therapy parameters in Medtronic apps.","url":"https://insights.sbomify.com/CVE-2023-25931/"}