{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2023-25948 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-25948 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-25948 is a high-severity vulnerability in Honeywell Direct Station, published on 13 Jul 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-25948 and fix it if it is affected.\n\nWhat it is: CVE-2023-25948 is a high-severity vulnerability in Honeywell Direct Station, published on 13 Jul 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-25948 in the wild and no public exploit code.\n\nAffected product: Honeywell Direct Station. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-25948/ (Markdown: https://insights.sbomify.com/CVE-2023-25948/index.md)","id":"CVE-2023-25948","markdown":"https://insights.sbomify.com/CVE-2023-25948/index.md","name":"CVE-2023-25948","record":{"aliases":["GHSA-7fv4-25h2-46hc"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Experion control system","requires_auth":"none","summary":"Attackers can leak configuration data from Honeywell Experion servers by sending specially crafted messages that trigger errors.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Honeywell","cpe":[{"product":"direct_station","vendor":"honeywell"},{"product":"engineering_station","vendor":"honeywell"},{"product":"experion_server","vendor":"honeywell"},{"product":"experion_station","vendor":"honeywell"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-209","name":"Generation of Error Message Containing Sensitive Information"},{"id":"CWE-394","name":"Unexpected Status Code or Return Value"}],"description":"Server information leak of configuration data when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Server Data type confusion - info leak","id":"CVE-2023-25948","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Intel(R) Aptio* V UEFI Firmware Integrator Tools","id":"CVE-2023-25949"},"packages":[],"prev":{"headline":"The bundle management subsystem has a improper input validation when installing a HAP package.","id":"CVE-2023-25947"},"products":["Direct Station","Engineering Station","Experion Server","Experion Station"],"published":"2023-07-13","related":[{"cvss_score":9.8,"headline":"Server DoS due to heap overflow","id":"CVE-2023-23585","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":9.8,"headline":"DoS due to heap overflow","id":"CVE-2023-25078","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":7.5,"headline":"Server bad parsing implementation - stack overflow in server::get_db_path_for_driver","id":"CVE-2023-22435","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":7.5,"headline":"Server deserialization missing boundary checks - heap overflow in communication between server and controller","id":"CVE-2023-24474","kev_date_added":null,"published":"2023-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-05","vendors":["Honeywell"]},"summary":"Attackers can leak configuration data from Honeywell Experion servers by sending specially crafted messages that trigger errors.","url":"https://insights.sbomify.com/CVE-2023-25948/"}