{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-2685 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-2685 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-2685 is a high-severity vulnerability in ABB AO-OPC, published on 28 Jul 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-2685 and fix it if it is affected.\n\nWhat it is: CVE-2023-2685 is a high-severity vulnerability in ABB AO-OPC, published on 28 Jul 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-2685 in the wild and no public exploit code.\n\nAffected product: ABB AO-OPC. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-2685/ (Markdown: https://insights.sbomify.com/CVE-2023-2685/index.md)","id":"CVE-2023-2685","markdown":"https://insights.sbomify.com/CVE-2023-2685/index.md","name":"CVE-2023-2685","record":{"aliases":["GHSA-2rjc-3f9w-ghg6"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ABB AO-OPC server","requires_auth":"high_privilege","summary":"Attackers with write access to system folders can execute arbitrary code with system privileges via unquoted service paths in ABB AO-OPC.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[{"product":"ao-opc","vendor":"abb"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-428","name":"Unquoted Search Path or Element"}],"description":"A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges.\n\nIt is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders.\n\nAn update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unquoted Service Path in ABB AO-OPC","id":"CVE-2023-2685","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Gecko Platform","id":"CVE-2023-2686"},"packages":[],"prev":{"headline":"File Renaming on Upload \u003c 2.5.2 - Admin+ Stored Cross-Site Scripting","id":"CVE-2023-2684"},"products":["AO-OPC"],"published":"2023-07-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-10-21","vendors":["ABB"]},"summary":"Attackers with write access to system folders can execute arbitrary code with system privileges via unquoted service paths in ABB AO-OPC.","url":"https://insights.sbomify.com/CVE-2023-2685/"}