{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-28003 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-28003 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-28003 is a medium-severity authentication bypass vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert, published on 18 Apr 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-28003 and fix it if it is affected.\n\nWhat it is: CVE-2023-28003 is a medium-severity authentication bypass vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert, published on 18 Apr 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-28003 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Power Monitoring Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-28003/ (Markdown: https://insights.sbomify.com/CVE-2023-28003/index.md)","id":"CVE-2023-28003","markdown":"https://insights.sbomify.com/CVE-2023-28003/index.md","name":"CVE-2023-28003","record":{"aliases":["GHSA-wx2q-8m6x-v282"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"low_privilege","summary":"Attackers can maintain unauthorized access via hijacked sessions after user logout in Schneider Electric EcoStruxure Power Monitoring Expert.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric"}],"cvss":{"score":6.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-613","name":"DEPRECATED: Insufficient Session Expiration"}],"description":"A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to\nmaintain unauthorized access over a hijacked session in PME after the legitimate user has\nsigned out of their account.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in EcoStruxure Power Monitoring Expert","id":"CVE-2023-28003","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in PowerLogic HDPM6000","id":"CVE-2023-28004"},"packages":[],"prev":{"headline":"Security feature bypass in FortiOS","id":"CVE-2023-28002"},"products":["EcoStruxure Power Monitoring Expert"],"published":"2023-04-18","related":[{"cvss_score":9.8,"headline":"Deserialization in EcoStruxure Power Monitoring Expert","id":"CVE-2023-5391","kev_date_added":null,"published":"2023-10-04"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22727","kev_date_added":null,"published":"2022-02-04"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22826","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22827","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.5,"headline":"Deserialization in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-11739","kev_date_added":null,"published":"2026-03-10"},{"cvss_score":8.2,"headline":"Open redirect in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2023-5986","kev_date_added":null,"published":"2023-11-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Schneider Electric"]},"summary":"Attackers can maintain unauthorized access via hijacked sessions after user logout in Schneider Electric EcoStruxure Power Monitoring Expert.","url":"https://insights.sbomify.com/CVE-2023-28003/"}