CVE-2023-29114 Unauthorized System Log Disclosure in Enel X JuiceBox

Medium 5.7 Published Updated

An attacker can access system logs via the web interface to obtain plaintext credentials and sensitive configuration data from the Enel X JuiceBox EV charger.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Local or same network only
Victim action needed
Not needed
Fix
None listed

What is CVE-2023-29114?

CVE-2023-29114 is a medium-severity vulnerability in Enel X JuiceBox Pro 3.0 22kW Cellular, published on 5 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.

Official description

System logs could be accessed through web management application due to a lack of access control.

An attacker can obtain the following sensitive information:

•     Wi-Fi access point credentials to which the EV charger can connect.

•     APN web address and credentials.

•     IPSEC credentials.

•     Web interface access credentials for user and admin accounts.

•     JuiceBox system components (software installed, model, firmware version, etc.).

•     C2G configuration details.

•     Internal IP addresses.

•     OTA firmware update configurations (DNS servers).

All the credentials are stored in logs in an unencrypted plaintext format.

Weakness: CWE-200

Which versions are affected by CVE-2023-29114?

How do I fix CVE-2023-29114?

No fix has been published for CVE-2023-29114 yet. Limit exposure of the affected software until one is available.

Is CVE-2023-29114 being exploited?

There is no known exploitation of CVE-2023-29114 in the wild and no public exploit code.

Sources

Also known as GHSA-m9fp-x7x4-9799.

Is CVE-2023-29114 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.