{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-29414 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-29414 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-29414 is a high-severity memory corruption vulnerability in Schneider Electric Accutech Manager, published on 12 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-29414 and fix it if it is affected.\n\nWhat it is: CVE-2023-29414 is a high-severity memory corruption vulnerability in Schneider Electric Accutech Manager, published on 12 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-29414 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Accutech Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-29414/ (Markdown: https://insights.sbomify.com/CVE-2023-29414/index.md)","id":"CVE-2023-29414","markdown":"https://insights.sbomify.com/CVE-2023-29414/index.md","name":"CVE-2023-29414","record":{"aliases":["GHSA-3359-8r4q-9r9p"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Accutech Manager","requires_auth":"low_privilege","summary":"A local buffer overflow in Schneider Electric Accutech Manager allows local users to escalate privileges via specific string input.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"accutech_manager","vendor":"schneider-electric"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Accutech Manager","id":"CVE-2023-29414","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in n/a","id":"CVE-2023-29415"},"packages":[],"prev":{"headline":"Missing authorization in APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)","id":"CVE-2023-29413"},"products":["Accutech Manager"],"published":"2023-07-12","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2013-0658","kev_date_added":null,"published":"2013-02-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-07","vendors":["Schneider Electric"]},"summary":"A local buffer overflow in Schneider Electric Accutech Manager allows local users to escalate privileges via specific string input.","url":"https://insights.sbomify.com/CVE-2023-29414/"}