{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-29464 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-29464 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-29464 is a high-severity vulnerability in Rockwell Automation FactoryTalk Linx , published on 13 Oct 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-29464 and fix it if it is affected.\n\nWhat it is: CVE-2023-29464 is a high-severity vulnerability in Rockwell Automation FactoryTalk Linx , published on 13 Oct 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-29464 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation FactoryTalk Linx . No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-29464/ (Markdown: https://insights.sbomify.com/CVE-2023-29464/index.md)","id":"CVE-2023-29464","markdown":"https://insights.sbomify.com/CVE-2023-29464/index.md","name":"CVE-2023-29464","record":{"aliases":["GHSA-4v9x-wfx7-57r9"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial automation software","requires_auth":"none","summary":"Unauthenticated attackers can read memory and cause denial of service in Rockwell FactoryTalk Linx via crafted packets.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[{"product":"factorytalk_linx","vendor":"rockwellautomation"}],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-20","name":"Improper Input Validation"}],"description":"FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure","id":"CVE-2023-29464","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in n/a","id":"CVE-2023-29465"},"packages":[],"prev":{"headline":"Pavilion8 Security Misconfiguration Vulnerability","id":"CVE-2023-29463"},"products":["FactoryTalk Linx "],"published":"2023-10-13","related":[{"cvss_score":9.8,"headline":"Memory corruption in FactoryTalk Linx","id":"CVE-2020-27251","kev_date_added":null,"published":"2020-11-26"},{"cvss_score":9.8,"headline":"Path traversal in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-12001","kev_date_added":null,"published":"2020-06-15"},{"cvss_score":8.5,"headline":"Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities","id":"CVE-2025-9067","kev_date_added":null,"published":"2025-10-14"},{"cvss_score":8.5,"headline":"Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities","id":"CVE-2025-9068","kev_date_added":null,"published":"2025-10-14"},{"cvss_score":8.4,"headline":"Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability","id":"CVE-2025-7972","kev_date_added":null,"published":"2025-08-14"},{"cvss_score":8.1,"headline":"Code injection in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-11999","kev_date_added":null,"published":"2020-06-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Rockwell Automation"]},"summary":"Unauthenticated attackers can read memory and cause denial of service in Rockwell FactoryTalk Linx via crafted packets.","url":"https://insights.sbomify.com/CVE-2023-29464/"}