{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-30559 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-30559 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-30559 is a medium-severity vulnerability in Becton Dickinson \u0026 Co  BD Alaris™ Point-of-Care Unit (PCU) Model 8015, published on 13 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-30559 and fix it if it is affected.\n\nWhat it is: CVE-2023-30559 is a medium-severity vulnerability in Becton Dickinson \u0026 Co  BD Alaris™ Point-of-Care Unit (PCU) Model 8015, published on 13 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-30559 in the wild and no public exploit code.\n\nAffected product: Becton Dickinson \u0026 Co  BD Alaris™ Point-of-Care Unit (PCU) Model 8015. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-30559/ (Markdown: https://insights.sbomify.com/CVE-2023-30559/index.md)","id":"CVE-2023-30559","markdown":"https://insights.sbomify.com/CVE-2023-30559/index.md","name":"CVE-2023-30559","record":{"aliases":["GHSA-f4m8-c8f7-hw6q"],"analysis":{"component_type":"hardware_firmware","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device firmware","requires_auth":"none","summary":"Attackers can modify unsigned wireless card firmware to execute arbitrary code on BD Alaris Point-of-Care Units.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"BD","cpe":[{"product":"alaris_8015_pcu_firmware","vendor":"bd"}],"cvss":{"score":5.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"},{"id":"CWE-20","name":"Improper Input Validation"}],"description":"The firmware update package for the wireless card is not properly signed and can be modified.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Wireless Card Firmware Improperly Signed","id":"CVE-2023-30559","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"PCU Configuration Lacks Authentication","id":"CVE-2023-30560"},"packages":[],"prev":{"headline":"Multiple SQL injections in sql/data_dictionary.py table_list method in Archery - GHSL-2022-105","id":"CVE-2023-30558"},"products":["BD Alaris™ Point-of-Care Unit (PCU) Model 8015"],"published":"2023-07-13","related":[{"cvss_score":7.5,"headline":"Auth bypass in BD Alaris PC Unit and BD Alaris Systems Manager","id":"CVE-2020-25165","kev_date_added":null,"published":"2020-11-13"},{"cvss_score":6.8,"headline":"PCU Configuration Lacks Authentication","id":"CVE-2023-30560","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":6.1,"headline":"Lack of Cryptographic Security of IUI Bus","id":"CVE-2023-30561","kev_date_added":null,"published":"2023-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Becton Dickinson \u0026 Co "]},"summary":"Attackers can modify unsigned wireless card firmware to execute arbitrary code on BD Alaris Point-of-Care Units.","url":"https://insights.sbomify.com/CVE-2023-30559/"}