{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-30561 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-30561 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-30561 is a medium-severity vulnerability in Becton Dickinson \u0026 Co BD Alarisâ„¢ Point-of-Care Unit (PCU) Model 8015, published on 13 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-30561 and fix it if it is affected.\n\nWhat it is: CVE-2023-30561 is a medium-severity vulnerability in Becton Dickinson \u0026 Co BD Alarisâ„¢ Point-of-Care Unit (PCU) Model 8015, published on 13 Jul 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-30561 in the wild and no public exploit code.\n\nAffected product: Becton Dickinson \u0026 Co BD Alarisâ„¢ Point-of-Care Unit (PCU) Model 8015. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-30561/ (Markdown: https://insights.sbomify.com/CVE-2023-30561/index.md)","id":"CVE-2023-30561","markdown":"https://insights.sbomify.com/CVE-2023-30561/index.md","name":"CVE-2023-30561","record":{"aliases":["GHSA-6vvg-j24w-vf35"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical infusion pump","requires_auth":"none","summary":"Attackers with physical access can read or modify infusion data due to lack of cryptographic security on the internal bus.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"BD","cpe":[{"product":"alaris_8015_pcu_firmware","vendor":"bd"}],"cvss":{"score":6.1,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-311","name":"Missing Encryption of Sensitive Data"}],"description":"The data flowing between the PCU and its modules is insecure. A threat actor with physical access could potentially read or modify data by attaching a specially crafted device while an infusion is running.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Lack of Cryptographic Security of IUI Bus","id":"CVE-2023-30561","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Lack of Dataset Integrity Checking","id":"CVE-2023-30562"},"packages":[],"prev":{"headline":"PCU Configuration Lacks Authentication","id":"CVE-2023-30560"},"products":["BD Alarisâ„¢ Point-of-Care Unit (PCU) Model 8015"],"published":"2023-07-13","related":[{"cvss_score":7.5,"headline":"Auth bypass in BD Alaris PC Unit and BD Alaris Systems Manager","id":"CVE-2020-25165","kev_date_added":null,"published":"2020-11-13"},{"cvss_score":6.8,"headline":"PCU Configuration Lacks Authentication","id":"CVE-2023-30560","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":5.2,"headline":"Wireless Card Firmware Improperly Signed","id":"CVE-2023-30559","kev_date_added":null,"published":"2023-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-10-22","vendors":["Becton Dickinson \u0026 Co"]},"summary":"Attackers with physical access can read or modify infusion data due to lack of cryptographic security on the internal bus.","url":"https://insights.sbomify.com/CVE-2023-30561/"}