{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-30897 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-30897 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-30897 is a high-severity vulnerability in Siemens SIMATIC WinCC, published on 13 Jun 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-30897 and fix it if it is affected.\n\nWhat it is: CVE-2023-30897 is a high-severity vulnerability in Siemens SIMATIC WinCC, published on 13 Jun 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-30897 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC WinCC. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-30897/ (Markdown: https://insights.sbomify.com/CVE-2023-30897/index.md)","id":"CVE-2023-30897","markdown":"https://insights.sbomify.com/CVE-2023-30897/index.md","name":"CVE-2023-30897","record":{"aliases":["GHSA-chm6-c3vh-vvc3"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"SCADA HMI software","requires_auth":"low_privilege","summary":"An authenticated local attacker can escalate privileges and execute arbitrary code if a non-default installation path was used.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"wincc","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"A vulnerability has been identified in SIMATIC WinCC (All versions \u003c V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation.\r\n\r\nThis could allow an authenticated local attacker to inject arbitrary code and escalate privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in SIMATIC WinCC","id":"CVE-2023-30897","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization in Siveillance Video 2020 R2","id":"CVE-2023-30898"},"packages":[],"prev":{"headline":"WordPress XML for Google Merchant Center Plugin \u003c= 3.0.1 is vulnerable to Cross Site Scripting (XSS)","id":"CVE-2023-30877"},"products":["SIMATIC WinCC"],"published":"2023-06-13","related":[{"cvss_score":6.8,"headline":"Auth bypass in n/a","id":"CVE-2015-2823","kev_date_added":null,"published":"2015-04-08"},{"cvss_score":6.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2013-4911","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2013-4912","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2012-3003","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5.5,"headline":"Code injection in n/a","id":"CVE-2012-2596","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5,"headline":"Weak cryptography in n/a","id":"CVE-2015-1358","kev_date_added":null,"published":"2015-02-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-01-03","vendors":["Siemens"]},"summary":"An authenticated local attacker can escalate privileges and execute arbitrary code if a non-default installation path was used.","url":"https://insights.sbomify.com/CVE-2023-30897/"}