{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-31175 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-31175 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-31175 is a high-severity vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, published on 31 Aug 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-31175 and fix it if it is affected.\n\nWhat it is: CVE-2023-31175 is a high-severity vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, published on 31 Aug 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-31175 in the wild and no public exploit code.\n\nAffected product: Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-31175/ (Markdown: https://insights.sbomify.com/CVE-2023-31175/index.md)","id":"CVE-2023-31175","markdown":"https://insights.sbomify.com/CVE-2023-31175/index.md","name":"CVE-2023-31175","record":{"aliases":["GHSA-84qj-w5f9-c492"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SEL Grid Configurator","requires_auth":"low_privilege","summary":"Attackers can execute system commands with highest privileges on SEL Grid Configurator, requiring an upgrade to mitigate.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SEL","cpe":[{"product":"sel-5037_sel_grid_configurator","vendor":"selinc"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"},{"id":"CWE-250","name":"Execution with Unnecessary Privileges"}],"description":"An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Execution with Unnecessary Privileges","id":"CVE-2023-31175","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2023"},"n_packages":0,"n_references":2,"next":{"headline":"Insufficient entropy vulnerability could lead to authentication bypass","id":"CVE-2023-31176"},"packages":[],"prev":{"headline":"Cross-Site Request Forgery (CSRF)","id":"CVE-2023-31174"},"products":["SEL-5037 SEL Grid Configurator"],"published":"2023-08-31","related":[{"cvss_score":8.2,"headline":"Missing Authentication for Critical Function","id":"CVE-2023-34392","kev_date_added":null,"published":"2023-08-31"},{"cvss_score":7.7,"headline":"Use of Hard-coded Credentials","id":"CVE-2023-31173","kev_date_added":null,"published":"2023-08-31"},{"cvss_score":7.4,"headline":"Cross-Site Request Forgery (CSRF)","id":"CVE-2023-31174","kev_date_added":null,"published":"2023-08-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-10-01","vendors":["Schweitzer Engineering Laboratories"]},"summary":"Attackers can execute system commands with highest privileges on SEL Grid Configurator, requiring an upgrade to mitigate.","url":"https://insights.sbomify.com/CVE-2023-31175/"}