{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-32474 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-32474 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-32474 is a medium-severity path traversal vulnerability in Dell Display Manager, published on 6 Feb 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-32474 and fix it if it is affected.\n\nWhat it is: CVE-2023-32474 is a medium-severity path traversal vulnerability in Dell Display Manager, published on 6 Feb 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-32474 in the wild and no public exploit code.\n\nAffected product: Dell Display Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-32474/ (Markdown: https://insights.sbomify.com/CVE-2023-32474/index.md)","id":"CVE-2023-32474","markdown":"https://insights.sbomify.com/CVE-2023-32474/index.md","name":"CVE-2023-32474","record":{"aliases":["GHSA-959v-9j99-99w5"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Dell Display Manager","requires_auth":"low_privilege","summary":"A local attacker can exploit insecure junction handling during installation to delete arbitrary files or folders.","user_interaction":"required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"display_manager","vendor":"dell"}],"cvss":{"score":6.6,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-59","name":"Improper Link Resolution Before File Access"},{"id":"CWE-1386","name":"Insecure Operation on Windows Junction / Mount Point"}],"description":"Dell Display Manager application, version 2.1.1.17 and prior, contain an insecure operation on windows junction/mount point. A local malicious user could potentially exploit this vulnerability during installation leading to arbitrary folder or file deletion","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in Dell Display Manager","id":"CVE-2023-32474","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Security feature bypass in CPG BIOS","id":"CVE-2023-32475"},"packages":[],"prev":{"headline":"Memory corruption in PowerSwitch Z9664F-ON BIOS","id":"CVE-2023-32472"},"products":["Dell Display Manager"],"published":"2024-02-06","related":[{"cvss_score":7.3,"headline":"Privilege escalation in Dell Display Manager","id":"CVE-2023-32451","kev_date_added":null,"published":"2024-02-06"},{"cvss_score":7.3,"headline":"Privilege escalation in Dell Display Manager","id":"CVE-2023-28047","kev_date_added":null,"published":"2023-04-20"},{"cvss_score":6.7,"headline":"Race condition in Dell Display Manager","id":"CVE-2025-22394","kev_date_added":null,"published":"2025-01-15"},{"cvss_score":6.6,"headline":"Race condition in Dell Display Manager","id":"CVE-2025-21101","kev_date_added":null,"published":"2025-01-15"},{"cvss_score":6.6,"headline":"Privilege escalation in Dell Display Manager","id":"CVE-2023-28046","kev_date_added":null,"published":"2023-04-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Dell"]},"summary":"A local attacker can exploit insecure junction handling during installation to delete arbitrary files or folders.","url":"https://insights.sbomify.com/CVE-2023-32474/"}