{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-34392 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-34392 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-34392 is a high-severity missing authorization vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, published on 31 Aug 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-34392 and fix it if it is affected.\n\nWhat it is: CVE-2023-34392 is a high-severity missing authorization vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, published on 31 Aug 2023. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-34392 in the wild and no public exploit code.\n\nAffected product: Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-34392/ (Markdown: https://insights.sbomify.com/CVE-2023-34392/index.md)","id":"CVE-2023-34392","markdown":"https://insights.sbomify.com/CVE-2023-34392/index.md","name":"CVE-2023-34392","record":{"aliases":["GHSA-fqhh-mfcp-4mcw"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SEL Grid Configurator","requires_auth":"low_privilege","summary":"An attacker can execute arbitrary commands on managed devices due to missing authentication in the SEL Grid Configurator.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SEL","cpe":[{"product":"sel-5037_sel_grid_configurator","vendor":"selinc"}],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing Authentication for Critical Function","id":"CVE-2023-34392","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2023"},"n_packages":0,"n_references":2,"next":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority because it is Unused","id":"CVE-2023-34393"},"packages":[],"prev":{"headline":"Insecure Inherited Permissions","id":"CVE-2023-34391"},"products":["SEL-5037 SEL Grid Configurator"],"published":"2023-08-31","related":[{"cvss_score":8.8,"headline":"Execution with Unnecessary Privileges","id":"CVE-2023-31175","kev_date_added":null,"published":"2023-08-31"},{"cvss_score":7.7,"headline":"Use of Hard-coded Credentials","id":"CVE-2023-31173","kev_date_added":null,"published":"2023-08-31"},{"cvss_score":7.4,"headline":"Cross-Site Request Forgery (CSRF)","id":"CVE-2023-31174","kev_date_added":null,"published":"2023-08-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-10-01","vendors":["Schweitzer Engineering Laboratories"]},"summary":"An attacker can execute arbitrary commands on managed devices due to missing authentication in the SEL Grid Configurator.","url":"https://insights.sbomify.com/CVE-2023-34392/"}