{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-34406 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-34406 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-34406 is a low-severity vulnerability in n/a, published on 13 Feb 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-34406 and fix it if it is affected.\n\nWhat it is: CVE-2023-34406 is a low-severity vulnerability in n/a, published on 13 Feb 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-34406 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-34406/ (Markdown: https://insights.sbomify.com/CVE-2023-34406/index.md)","id":"CVE-2023-34406","markdown":"https://insights.sbomify.com/CVE-2023-34406/index.md","name":"CVE-2023-34406","record":{"aliases":["GHSA-fc4h-jq3v-6rrg"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Mercedes Benz NTG 6","requires_auth":"none","summary":"An attacker with local USB access can cause a denial of service in Mercedes Benz NTG 6 head units via an integer overflow in user data import/export.","user_interaction":"required","vuln_class":"integer_overflow"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"headunit_ntg6_mercedes-benz_user_experience","vendor":"mercedes-benz"}],"cvss":{"score":3.3,"severity":"low","source":"cisa-adp","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-190","name":"Integer Overflow or Wraparound"}],"description":"An issue was discovered on Mercedes Benz NTG 6. A possible integer overflow exists in the user data import/export function of NTG (New Telematics Generation) 6 head units. To perform this attack, local access to USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Integer overflow in n/a","id":"CVE-2023-34406","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"integer_overflow","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in n/a","id":"CVE-2023-34407"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2023-34404"},"products":["n/a"],"published":"2025-02-13","related":[{"cvss_score":9.8,"headline":"Integer overflow in n/a","id":"CVE-2023-34399","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":7.7,"headline":"Path traversal in n/a","id":"CVE-2023-34402","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":7.5,"headline":"Denial of service in n/a","id":"CVE-2023-34397","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":7.5,"headline":"Null dereference in n/a","id":"CVE-2023-34398","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":7.5,"headline":"Null dereference in n/a","id":"CVE-2023-34400","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":6.8,"headline":"Memory corruption in n/a","id":"CVE-2024-37600","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":4.9,"headline":"Path traversal in n/a","id":"CVE-2023-34403","kev_date_added":null,"published":"2025-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-17","vendors":["n/a"]},"summary":"An attacker with local USB access can cause a denial of service in Mercedes Benz NTG 6 head units via an integer overflow in user data import/export.","url":"https://insights.sbomify.com/CVE-2023-34406/"}