CVE-2023-35796 Cross-site scripting in SINEMA Server V14
An attacker with access to a monitored device can inject malicious scripts into SINEMA Server, leading to arbitrary code execution with SYSTEM privileges.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- A user has to click or open something
- Fix
- None listed
What is CVE-2023-35796?
CVE-2023-35796 is a high-severity cross-site scripting vulnerability in Siemens SINEMA Server V14, published on 10 Oct 2023. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.
Official description
A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)
Weakness: CWE-79
Which versions are affected by CVE-2023-35796?
It affects 1 product.
Products include Siemens Sinema Server.
How do I fix CVE-2023-35796?
No fix has been published for CVE-2023-35796 yet. Limit exposure of the affected software until one is available.
Escape output for the context it lands in and set a strict Content Security Policy. Upgrading the affected component is the real fix. More about Cross-site scripting.
Is CVE-2023-35796 being exploited?
There is no known exploitation of CVE-2023-35796 in the wild and no public exploit code.
Other vulnerabilities in Siemens SINEMA Server V14