{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-39167 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-39167 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-39167 is a high-severity missing authorization vulnerability in SENEC Storage Box V1, published on 7 Dec 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-39167 and fix it if it is affected.\n\nWhat it is: CVE-2023-39167 is a high-severity missing authorization vulnerability in SENEC Storage Box V1, published on 7 Dec 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-39167 in the wild and no public exploit code.\n\nAffected product: SENEC Storage Box V1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-39167/ (Markdown: https://insights.sbomify.com/CVE-2023-39167/index.md)","id":"CVE-2023-39167","markdown":"https://insights.sbomify.com/CVE-2023-39167/index.md","name":"CVE-2023-39167","record":{"aliases":["GHSA-vjcv-792v-vg3p"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SENEC Storage Box","requires_auth":"none","summary":"Unauthenticated attackers can access sensitive log files on SENEC Storage Box devices due to improper access control.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[{"product":"senec_storage_box_firmware","vendor":"enbw"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"}],"description":"In SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices' logfiles that contain sensitive data.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SENEC: Storage Box V1,V2 and V3 affected by improper access control vulnerability","id":"CVE-2023-39167","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority because it's a duplicate of CVE-2023-39167.","id":"CVE-2023-39168"},"packages":[],"prev":{"headline":"WordPress tagDiv Composer Plugin \u003c 4.4 is vulnerable to Cross Site Request Forgery (CSRF)","id":"CVE-2023-39166"},"products":["Storage Box V1","Storage Box V2","Storage Box V3"],"published":"2023-12-07","related":[{"cvss_score":9.8,"headline":"SENEC: Storage Box V1,V2 and V3 using default credentials","id":"CVE-2023-39169","kev_date_added":null,"published":"2023-12-07"},{"cvss_score":9.1,"headline":"SENEC: Storage Box V1,V2 and V3 transmitting sensitive data unencrypted","id":"CVE-2023-39172","kev_date_added":null,"published":"2023-12-07"},{"cvss_score":7.2,"headline":"SENEC Storage Box V1,V2 and V3 accidentially expose a management interface","id":"CVE-2023-39171","kev_date_added":null,"published":"2023-12-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-11-04","vendors":["SENEC"]},"summary":"Unauthenticated attackers can access sensitive log files on SENEC Storage Box devices due to improper access control.","url":"https://insights.sbomify.com/CVE-2023-39167/"}