{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2023-41552 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-41552 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-41552 is a critical memory corruption vulnerability in Tenda Ac7 Firmware, published on 30 Aug 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-41552 and fix it if it is affected.\n\nWhat it is: CVE-2023-41552 is a critical memory corruption vulnerability in Tenda Ac7 Firmware, published on 30 Aug 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-41552 in the wild and no public exploit code.\n\nAffected product: Tenda Ac7 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-41552/ (Markdown: https://insights.sbomify.com/CVE-2023-41552/index.md)","id":"CVE-2023-41552","markdown":"https://insights.sbomify.com/CVE-2023-41552/index.md","name":"CVE-2023-41552","record":{"aliases":["GHSA-w57p-72jv-7755"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda wireless router","requires_auth":"none","summary":"A stack overflow in Tenda AC7 and AC9 routers allows attackers to execute arbitrary code or cause denial of service via the ssid parameter.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ac7_firmware","vendor":"tenda"},{"product":"ac9_firmware","vendor":"tenda"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"description":"Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2023-41552","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac7_firmware","products":["tenda:ac7_firmware","tenda:ac9_firmware"],"type":"memory_corruption","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in n/a","id":"CVE-2023-41553"},"packages":[],"prev":{"headline":"JeecgBoot server-side template injection","id":"CVE-2023-41544"},"products":["n/a"],"published":"2023-08-30","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51843","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51844","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51845","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51846","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29135","kev_date_added":null,"published":"2025-03-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29137","kev_date_added":null,"published":"2025-03-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32301","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-10-01","vendors":["n/a"]},"summary":"A stack overflow in Tenda AC7 and AC9 routers allows attackers to execute arbitrary code or cause denial of service via the ssid parameter.","url":"https://insights.sbomify.com/CVE-2023-41552/"}