{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-41967 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-41967 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-41967 is a low-severity vulnerability in Gallagher Controller 6000, published on 18 Dec 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-41967 and fix it if it is affected.\n\nWhat it is: CVE-2023-41967 is a low-severity vulnerability in Gallagher Controller 6000, published on 18 Dec 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-41967 in the wild and no public exploit code.\n\nAffected product: Gallagher Controller 6000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-41967/ (Markdown: https://insights.sbomify.com/CVE-2023-41967/index.md)","id":"CVE-2023-41967","markdown":"https://insights.sbomify.com/CVE-2023-41967/index.md","name":"CVE-2023-41967","record":{"aliases":["GHSA-g2fv-w76j-v7p7"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Gallagher Controller 6000","requires_auth":"none","summary":"An attacker with physical access and the default diagnostic password can view sensitive configuration data via diagnostic web pages.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[{"product":"controller_6000_firmware","vendor":"gallagher"}],"cvss":{"score":2.4,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-212","name":"Improper Removal of Sensitive Information Before Storage or Transfer"},{"id":"CWE-1272","name":"Sensitive Information Uncleared Before Debug/Power State Transition"}],"description":"Sensitive information uncleared after debug/power state transition in the Controller 6000 could be abused by an attacker with knowledge of the Controller's default diagnostic password and physical access to the Controller to view its configuration through the diagnostic web pages. \n\nThis issue affects: Gallagher Controller 6000 8.70 prior to vCR8.70.231204a (distributed in 8.70.2375 (MR5)), v8.60 or earlier.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Controller 6000","id":"CVE-2023-41967","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in iOS and iPadOS","id":"CVE-2023-41968"},"packages":[],"prev":{"headline":"Sielco Radio Link and Analog FM Transmitters Privilege Defined With Unsafe Actions","id":"CVE-2023-41966"},"products":["Controller 6000"],"published":"2023-12-18","related":[{"cvss_score":7.5,"headline":"Other in Controller 6000","id":"CVE-2023-24590","kev_date_added":null,"published":"2023-12-18"},{"cvss_score":7.5,"headline":"Controller 6000 buffer overflow via upload feature in web interface","id":"CVE-2023-24584","kev_date_added":null,"published":"2023-06-01"},{"cvss_score":7.5,"headline":"Denial of service in Gallagher Controller 6000","id":"CVE-2022-26078","kev_date_added":null,"published":"2022-07-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Gallagher"]},"summary":"An attacker with physical access and the default diagnostic password can view sensitive configuration data via diagnostic web pages.","url":"https://insights.sbomify.com/CVE-2023-41967/"}