{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-42144 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-42144 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-42144 is a medium-severity vulnerability in n/a, published on 23 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-42144 and fix it if it is affected.\n\nWhat it is: CVE-2023-42144 is a medium-severity vulnerability in n/a, published on 23 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-42144 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-42144/ (Markdown: https://insights.sbomify.com/CVE-2023-42144/index.md)","id":"CVE-2023-42144","markdown":"https://insights.sbomify.com/CVE-2023-42144/index.md","name":"CVE-2023-42144","record":{"aliases":["GHSA-h5vq-7cj5-594m"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Shelly TRV","requires_auth":"low_privilege","summary":"A local attacker can obtain the Wi-Fi password due to cleartext transmission during the initial setup of the Shelly TRV device.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"trv_firmware","vendor":"shelly"}],"cvss":{"score":5.5,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Cleartext Transmission during initial setup in Shelly TRV 20220811-15234 v.2.1.8 allows a local attacker to obtain the Wi-Fi password.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2023-42144","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in n/a","id":"CVE-2023-42147"},"packages":[],"prev":{"headline":"Supply chain in n/a","id":"CVE-2023-42143"},"products":["n/a"],"published":"2024-01-23","related":[{"cvss_score":5.4,"headline":"Supply chain in n/a","id":"CVE-2023-42143","kev_date_added":null,"published":"2024-01-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-20","vendors":["n/a"]},"summary":"A local attacker can obtain the Wi-Fi password due to cleartext transmission during the initial setup of the Shelly TRV device.","url":"https://insights.sbomify.com/CVE-2023-42144/"}