{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-44120 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-44120 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-44120 is a high-severity vulnerability in Siemens Spectrum Power 7, published on 9 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-44120 and fix it if it is affected.\n\nWhat it is: CVE-2023-44120 is a high-severity vulnerability in Siemens Spectrum Power 7, published on 9 Jan 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-44120 in the wild and no public exploit code.\n\nAffected product: Siemens Spectrum Power 7. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-44120/ (Markdown: https://insights.sbomify.com/CVE-2023-44120/index.md)","id":"CVE-2023-44120","markdown":"https://insights.sbomify.com/CVE-2023-44120/index.md","name":"CVE-2023-44120","record":{"aliases":["GHSA-hv6m-386r-hchx"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens Spectrum Power 7","requires_auth":"low_privilege","summary":"An authenticated local attacker can exploit sudo misconfiguration to execute arbitrary code and gain root access on Siemens Spectrum Power 7.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"spectrum_power_7","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in Spectrum Power 7","id":"CVE-2023-44120","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"LG ThinQ Service - Intent redirection with system privilege/LaunchAnyWhere","id":"CVE-2023-44121"},"packages":[],"prev":{"headline":"Race condition in EMUI","id":"CVE-2023-44119"},"products":["Spectrum Power 7"],"published":"2024-01-09","related":[{"cvss_score":8.5,"headline":"Privilege escalation in Spectrum Power 7","id":"CVE-2024-29119","kev_date_added":null,"published":"2024-11-12"},{"cvss_score":8.2,"headline":"Privilege escalation in Spectrum Power 7","id":"CVE-2023-38557","kev_date_added":null,"published":"2023-09-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-14","vendors":["Siemens"]},"summary":"An authenticated local attacker can exploit sudo misconfiguration to execute arbitrary code and gain root access on Siemens Spectrum Power 7.","url":"https://insights.sbomify.com/CVE-2023-44120/"}