{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2023-4542 exists.","fix":"No fix has been published for CVE-2023-4542 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-4542 is a medium-severity command injection vulnerability in D-Link DAR-8000-10, published on 25 Aug 2023. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-4542 and fix it if it is affected.\n\nWhat it is: CVE-2023-4542 is a medium-severity command injection vulnerability in D-Link DAR-8000-10, published on 25 Aug 2023. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2023-4542 exists.\n\nAffected product: D-Link DAR-8000-10. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-4542/ (Markdown: https://insights.sbomify.com/CVE-2023-4542/index.md)","id":"CVE-2023-4542","markdown":"https://insights.sbomify.com/CVE-2023-4542/index.md","name":"CVE-2023-4542","record":{"aliases":["GHSA-85cp-hm7f-pwxw"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"D-Link DAR-8000-10","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary OS commands via the cmd argument in sys1.php on D-Link DAR-8000-10 devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"dar-8000-10_firmware","vendor":"dlink"}],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2023-08-09","github_poc":1,"max_poc_stars":2,"metasploit":0,"nuclei":1,"refs":[{"date":"2023-08-09T05:57:13Z","kind":"github_poc","ref":"https://github.com/PumpkinBridge/CVE-2023-4542","stars":2,"title":null},{"date":null,"kind":"nuclei","ref":"http/cves/2023/CVE-2023-4542.yaml","stars":null,"title":"D-Link DAR-8000-10 - Command Injection"}],"tier":"weaponised"},"has_fix":null,"headline":"D-Link DAR-8000-10 sys1.php os command injection","id":"CVE-2023-4542","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2023"},"n_packages":0,"n_references":3,"next":{"headline":"IBOS OA export\u0026contactids=x sql injection","id":"CVE-2023-4543"},"packages":[],"prev":{"headline":"SQLi in Weens Admin Panel","id":"CVE-2023-4541"},"products":["DAR-8000-10"],"published":"2023-08-25","related":[{"cvss_score":5.3,"headline":"D-Link DAR-8000-10 importhtml.php deserialization","id":"CVE-2024-4699","kev_date_added":null,"published":"2024-05-10"},{"cvss_score":5,"headline":"D-Link DAR-8000-10 decodmail.php os command injection","id":"CVE-2023-4711","kev_date_added":null,"published":"2023-09-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"MIT","name":"Nuclei templates"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-02","vendors":["D-Link"]},"summary":"Remote attackers can execute arbitrary OS commands via the cmd argument in sys1.php on D-Link DAR-8000-10 devices.","url":"https://insights.sbomify.com/CVE-2023-4542/"}