{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-48429 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-48429 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-48429 is a low-severity denial of service vulnerability in Siemens SINEC INS, published on 12 Dec 2023. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2023-48429 and fix it if it is affected.\n\nWhat it is: CVE-2023-48429 is a low-severity denial of service vulnerability in Siemens SINEC INS, published on 12 Dec 2023. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2023-48429 in the wild and no public exploit code.\n\nAffected product: Siemens SINEC INS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-48429/ (Markdown: https://insights.sbomify.com/CVE-2023-48429/index.md)","id":"CVE-2023-48429","markdown":"https://insights.sbomify.com/CVE-2023-48429/index.md","name":"CVE-2023-48429","record":{"aliases":["GHSA-hf2c-2hx8-m89f"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SINEC INS","requires_auth":"high_privilege","summary":"A malicious admin can crash the SINEC INS server by sending a crafted request with unchecked parameter lengths, causing a restart.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinec_ins","vendor":"siemens"}],"cvss":{"score":2.7,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-754","name":"Improper Check for Unusual or Exceptional Conditions"},{"id":"CWE-394","name":"Unexpected Status Code or Return Value"}],"description":"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in SINEC INS","id":"CVE-2023-48429","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in SINEC INS","id":"CVE-2023-48430"},"packages":[],"prev":{"headline":"Command injection in SINEC INS","id":"CVE-2023-48428"},"products":["SINEC INS"],"published":"2023-12-12","related":[{"cvss_score":9.9,"headline":"Path traversal in SINEC INS","id":"CVE-2022-45092","kev_date_added":null,"published":"2023-01-10"},{"cvss_score":9.4,"headline":"Path traversal in SINEC INS","id":"CVE-2024-46888","kev_date_added":null,"published":"2024-11-12"},{"cvss_score":9.4,"headline":"Command injection in SINEC INS","id":"CVE-2024-46890","kev_date_added":null,"published":"2024-11-12"},{"cvss_score":8.7,"headline":"Command injection in SINEC INS","id":"CVE-2026-46746","kev_date_added":null,"published":"2026-06-09"},{"cvss_score":8.7,"headline":"Privilege escalation in SINEC INS","id":"CVE-2026-46748","kev_date_added":null,"published":"2026-06-09"},{"cvss_score":8.5,"headline":"Path traversal in SINEC INS","id":"CVE-2022-45093","kev_date_added":null,"published":"2023-01-10"},{"cvss_score":8.4,"headline":"Command injection in SINEC INS","id":"CVE-2022-45094","kev_date_added":null,"published":"2023-01-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-02-25","vendors":["Siemens"]},"summary":"A malicious admin can crash the SINEC INS server by sending a crafted request with unchecked parameter lengths, causing a restart.","url":"https://insights.sbomify.com/CVE-2023-48429/"}