{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2023-49131 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2023-49131 yet. Limit exposure of the affected software until one is available.","what":"CVE-2023-49131 is a high-severity memory corruption vulnerability in Siemens Solid Edge SE2023, published on 9 Jan 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2023-49131 and fix it if it is affected.\n\nWhat it is: CVE-2023-49131 is a high-severity memory corruption vulnerability in Siemens Solid Edge SE2023, published on 9 Jan 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2023-49131 in the wild and no public exploit code.\n\nAffected product: Siemens Solid Edge SE2023. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2023-49131/ (Markdown: https://insights.sbomify.com/CVE-2023-49131/index.md)","id":"CVE-2023-49131","markdown":"https://insights.sbomify.com/CVE-2023-49131/index.md","name":"CVE-2023-49131","record":{"aliases":["GHSA-c5v6-g38c-9hgp"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"CAD software","requires_auth":"none","summary":"An attacker can execute arbitrary code by tricking a user into opening a malicious PAR file in Solid Edge.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"solid_edge_se2023","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-824","name":"Access of Uninitialized Pointer"}],"description":"A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49131","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2023"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49132"},"packages":[],"prev":{"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49130"},"products":["Solid Edge SE2023"],"published":"2024-01-09","related":[{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49121","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49122","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49123","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49124","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49126","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49127","kev_date_added":null,"published":"2024-01-09"},{"cvss_score":7.8,"headline":"Memory corruption in Solid Edge SE2023","id":"CVE-2023-49128","kev_date_added":null,"published":"2024-01-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-27","vendors":["Siemens"]},"summary":"An attacker can execute arbitrary code by tricking a user into opening a malicious PAR file in Solid Edge.","url":"https://insights.sbomify.com/CVE-2023-49131/"}